GN
NOTES
1. Coil operating power
2) Tape and reel packing
(A type)
(1)-1 Tape dimensions
1) As a general rule, only a pure DC pow-
er supply should be used for the coil drive.
2)To ensure proper operation, the voltage
applied to both terminals of the coil should
be ±5% (at 20°C 68°F) the rated operating
voltage of the coil. Also, be aware that the
pick-up and drop-out voltages will fluctu-
ate depending on the ambient tempera-
ture and operating conditions.
mm inch
Relay polarity bar
(Z type)
4.00
.157
11.50
.453
1.75
.069
1.50+0.1 dia
0
0
.059+.004 dia
2.00
.079
0.40
.016
24.00±0.3
.945±.012
11.10
.437
2.00dia
.079dia
16.00
.630
8.00
.315
10.70±0.2 GN relays
.421±.008
3) The ripple factor for the voltage applied
to the coil should be less than 5%.
4) For set and reset latching relays, the
rated operating voltage should be applied
to the coil for 10 ms or more.
Tape coming out direction
General tolerance ±0.1 mm .004 inch
(S type)
(1)-2 Tape dimensions
2. Coil connection
Relay polarity bar
4.00
.157
10.70±0.2
.421±.008
0.40
.016
2.00
2.0dia
(Z type)
1.50+0.1 dia .079
0
0
.079dia
When connecting coils, refer to the wiring
diagram to prevent mis-operation or mal-
function.
.059+.004 dia
1.75
.069
11.50
.453
24.00±0.3
.945±.012
11.10
.437
3. External magnetic field
GN relays
16.00
.630
6.3
.248
Tape coming out direction
Since GN relays are highly sensitive po-
larized relays, their characteristics will be
affected by a strong external magnetic
field. Avoid using the relay under that con-
ditions.
General tolerance ±0.1 mm .004 inch
(2) Dimensions of plastic peel
mm inch
4. Cleaning
21±0.8 dia.
.827±.031 dia.
In automatic cleaning, cleaning with the
boiling method is recommended. Avoid ul-
trasonic cleaning which subjects the relay
to high frequency vibrations. It may cause
the contacts to stick.
2.0±0.5
.079±.020
100±1 dia.
3.937±.039 dia.
lt is recommended that a fluorinated hy-
drocarbon or other alcoholic solvent be
used.
370±2 dia.
14.567±.079 dia.
13±0.2 dia.
.512±.008 dia.
2.0±0.2
.079±.008
24.4 +02
5. Packing style
.961 0+.079
1) The relay is packed in a tube with the
relay orientation mark on the left side, as
shown in the figure below.
6. Automatic insertion
To maintain the internal function of the
relay, the chucking pressure should not
exceed the values below.
Orientation (indicates PIN No.1)stripe
Chucking pressure in the direction A:
4.9 N {500gf} or less
Chucking pressure in the direction B:
9.8 N {1 kgf} or less
Stopper (green)
Stopper (red)
Chucking pressure in the direction C:
9.8 N {1 kgf} or less
C
B
A
Please chuck the
portion.
Avoid chucking the center of the relay.
In addition, excessive chucking pressure
to the pinpoint of the relay should be
avoided.
For Cautions for Use, see Relay Technical Information (Page 48 to 76).