欢迎访问ic37.com |
会员登录 免费注册
发布采购

AGQ210S03Z 参数 Datasheet PDF下载

AGQ210S03Z图片预览
型号: AGQ210S03Z
PDF下载: 下载PDF文件 查看货源
内容描述: 超小型平极化继电器 [ULTRA-SMALL PACKAGE FLAT POLARIZED RELAY]
分类和应用: 继电器光电二极管
文件页数/大小: 4 页 / 115 K
品牌: NAIS [ NAIS(MATSUSHITA ELECTRIC WORKS) ]
 浏览型号AGQ210S03Z的Datasheet PDF文件第2页浏览型号AGQ210S03Z的Datasheet PDF文件第3页浏览型号AGQ210S03Z的Datasheet PDF文件第4页  
GQ
TESTING
ULTRA-SMALL PACKAGE
FLAT POLARIZED RELAY
GQ-RELAYS
Due to highly efficient magnetic circuit de-
sign, leakage flux is reduced and changes
in electrical characteristics from compo-
nents being mounted close-together are
minimized. This all means a packaging
density higher than ever before.
• Nominal operating power: 140 mW
• Outstanding vibration and shock re-
sistance.
Functional shock resistance:
750 m/s
2
{75G}
Destructive shock resistance:
1,000 m/s
2
{100G}
Functional vibration resistance:
10 to 55 Hz (at double amplitude of 3.3
mm
.130 inch)
Destructive vibration resistance:
10 to 55 Hz (at double amplitude of 5 mm
.197 inch)
FEATURES
10.60±0.3
.417±.012
7.20±0.3
.283±.012
5.20±0.2
.205±.008
10.60±0.3
.417±.012
7.20±0.3
.283±.012
Max.5.40
.213
mm
inch
• Compact flat body saves space
With a small footprint of 10.6 mm (L)
×
7.2
mm (W)
.417 inch (L)
×
.283 inch (W)
for
space savings, it also has a very short
height of 5.2 mm
.205 inch.
(Standard PC
board type.)
• Outstanding surge resistance.
Surge withstand between open contacts:
1,500 V 10
×
160
µ
s (FCC part 68)
Surge withstand between contacts and
coil: 2,500 V 2
×
10
µ
s (Bellcore)
• The use of twin crossbar contacts en-
sures high contact reliability.
AgPd contact is used because of its good
sulfide resistance. Adopting low-gas
molding material. Coil assembly molding
technology which avoids generating vola-
tile gas from coil.
• Increased packaging density
SPECIFICATIONS
Contact
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1A )
Contact material
Nominal switching capacity
(resistive load)
Max. switching power
(resistive load)
Max. switching voltage
Max. switching current
Min. switching capacity
f
1
Nominal
operating
power
Single side stable
1 coil latching
Mechanical (at 180 cpm)
1 A 30 V DC
resistive
Electrical
(at 20 cpm) 0.3 A 125 V AC
resistive
2 Form C
100 m
Stationary: AgPd+Au clad
Movable: AgPd
1 A 30 V DC
0.3 A 125 V AC
30 W, 37.5 V A
110 V DC, 125 V AC
1A
10
µ
A 10 mV DC
140mW (1.5 to 12 V DC)
230mW (24 V DC)
100mW (1.5 to 12 V DC)
120mW (24 V DC)
5
×
10
7
Vibration resistance
10
5
10
5
Destructive
Conditions for opera- Ambient
tion, transport and
temperature
f
2
storage*
8
(Not freezing and con-
Humidity
densing at low tem-
perature)
Unit weight
Notes:
f
1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
f
2 The upper limit for the ambient temperature is the maximum temperature that
can satisfy the coil temperature rise. Under the packing condition, allowable
temperature range is from –40 to +70
°
C
–40
°
to +158
°
F.
Characteristics
Initial insulation resistance*
1
Initial
breakdown
voltage*
2
Between open contacts
Between contact sets
Min. 1,000M
(at 500V DC)
750 Vrms for 1min.
1,000 Vrms for 1min.
1,500 Vrms for 1min.
1,500 V(FCC Part 68)
2,500 V(Bellcore)
Max. 4 ms (Approx. 2 ms)
[Max. 4 ms (Approx. 2 ms)]
Max. 4 ms (Approx. 1 ms)
[Max. 4 ms (Approx. 2 ms)]
Max. 50
°
C
Min. 750 m/s
2
{75G]
Min. 1,000 m/s
2
{100G]
10 to 55 Hz at double
amplitude of 3.3 mm
10 to 55 Hz at double
amplitude of 5 mm
–40
°
C to 85
°
C
–40
°
F to 185
°
F
5 to 85% R.H.
Approx. 1 g
.035 oz
Between contacts and coil
Between open contacts
Initial surge (10
×
160
µ
s)
voltage
Between contacts and coil
(2
×
10
µ
s)
Operate time [Set time]*
3
(at 20
°
C)
Release time (without diode)
[Reset time]*
3
(at 20
°
C)
Temperature rise*
4
(at 20
°
C)
Functional*
5
Shock resistance
Destructive*
6
Functional*
7
Rating
Expected
life (min.
operations)
Remarks:
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as "Initial breakdown voltage" section.
*
2
Detection current: 10mA.
*
3
Nominal voltage applied to the coil, excluding contact bounce time.
*
4
By resistive method, nominal voltage applied to the coil; contact carrying current:
1 A.
*
5
Half-wave pulse of sine wave: 6 ms;detection time: 10
µ
s.
*
6
Half-wave pulse of sine wave: 6 ms.
*
7
Detection time: 10
µ
s
.
*
8
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61)
129