POWER PhotoMOS RELAYS
(Voltage Sensitive Type)
PhotoMOS
RELAYS
4. Both AC/DC dual types and DC-only
types are available
The AC/DC dual type is capable of bi-di-
rectional control, and unlike conventional
SSRs, does not have to be used different-
ly depending on the load. The DC-only
type is well suited for control of DC sole-
noids and DC motors.
5. High sensitivity, low ON resistance
A maximum 3.6 A load can be controlled
with the minimum input voltage of 4 V DC.
The ON resistance is also low at 0.09
Ω
(AQZ102D).
6. Small scale, slim type, 4-pin SIL
Length 21.0 mm
×
width 3.5 mm
×
height
12.5 mm. High precision mounting is pos-
sible because of the small 73.5mm
2
area
of the 4-pin SIL.
21±0.2
.827±.008
3.5±0.2
.138±.008
12.5±0.2
.492±.008
FEATURES
1. A voltage sensitive power Photo-
MOS relay
Conventional power PhotoMOS relays
are connected externally to an input limit-
ing resistor in order to obtain the appropri-
ate LED current. Adding an internal
constant-current element renders the in-
put limiting resistor unnecessary, making
it possible for the PhotoMOS relay to be
voltage driven.
2. Wide range of input voltages
Allows a wide range of input voltages from
4 to 30 V DC. The relay can be used in 5
V, 12 V or 24 V DC systems.
3. Large capacity PhotoMOS relay
Supports the various types of load con-
trol, from very small loads to a maximum
2.7 A for the AC/DC dual type, 3.6 A for
the DC-only type.
mm
inch
–
1
+
2
3
4
AC/DC type
–
1
+
2
–
3
+
4
DC type
TYPES
1. AC/DC type
Output rating
Load voltage
60 V
100 V
200 V
400 V
Load current
2.7 A
1.8 A
0.9 A
0.45 A
Part No.
AQZ202D
AQZ205D
AQZ207D
AQZ204D
25 pcs.
500 pcs.
Packing quantity
Inner carton
Outer carton
2. DC type
Output rating
Load voltage
60 V
100 V
200 V
400 V
Load current
3.6 A
2.3 A
1.1 A
0.6 A
Part No.
AQZ102D
AQZ105D
AQZ107D
AQZ104D
Packing quantity
Inner carton
Outer carton
25 pcs.
500 pcs.
Notes: Load voltage and current of AC/DC type: Peak AC/DC.
Load voltage and current of DC type: DC.
214