AUTOMOTIVE POWER
RELAYS — SMALL SIZE,
LIGHT WEIGHT AND
COMPLETELY WATER TIGHT
FEATURES
1. Small size and light weight
For space saving, the outside dimensions
of the main body are reduced to be 21.5
mm (length)
×
14.4 mm (width)
×
37 mm
(height)
(.846
×
.567
×
1.457 inch).
and
the weight is also reduced to be approx.
19 g
.67 oz
(Direct coupling 1 Form A,
1 Form B type)
2. Water tightness
Since the relays comply with the water
tightness standards, JIS D 0203, water
and dust will not enter the relay even if it is
mounted in the engine area.
CA-RELAYS
3. Low operaing power (1.4W) type is
available (1 Form A, 1 Form B)
4. Since the terminal arrangement
complies with JIS D5011 B4-M1, com-
mercial connectors are available for
these types of relays.
SPECIFICATIONS
Contact
Type
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1A)
Contact material
1 Form A
12 V DC
1 Form B
50 m ohm
silver alloy
0.3 V
After electrical life test,
0.3 V
0.4 V
by voltage drop
After electrical life test, After electrical life test,
12 V DC 20 A
by voltage drop
by voltage drop
(1.4 W type),
12 V DC 20 A
12 V DC 20 A
12 V DC 30 A
(1.8 W type)
20 A 12 V DC
(1.4 W type)
20 A 12 V DC
30 A 12 V DC
(1.8 W type)
16 V
15 V
120 A (1.4 W type)
120 A
150 A (1.8 W type)
20 A continuous
(1.4 W type)
20 A continuous
30 A for 1 min
(1.8 W type)
1.4 W / 1.8 W
10
10
(ON: 2s, OFF: 2s)
5
6
1 Form C
24 V DC
1 Form C
Contact voltage drop, max.
0.4 V
After electrical life test,
by voltage drop
24 V DC 10 A
Nominal switching capacity
(resistive load)
Max. switching voltage
Rating
Max. switching current
10 A 24 V DC
(ON: 2s, OFF: 2s)
30 V
50 A (Inrush current)
100 A
Max. carrying current
Nominal operating power
Expected
life (min.
operations)
Mechanical (at 120 cpm)
20 A
(1.4 W, 1.8 W type)
Electrical
30 A
(1.8 W type)
20 A continuous
1.8 W
5
×
10
5
10 A continuous
2
×
10
4
(ON: 3s, OFF: 15s)
10
5
(ON 2s, OFF 2s)
10
5
383