欢迎访问ic37.com |
会员登录 免费注册
发布采购

DS2E-SL2-DC5V 参数 Datasheet PDF下载

DS2E-SL2-DC5V图片预览
型号: DS2E-SL2-DC5V
PDF下载: 下载PDF文件 查看货源
内容描述: 高灵敏1500 V FCC SURGE可承受小型继电器 [HIGHLY SENSITIVE 1500 V FCC SURGE WITHSTANDING MINIATURE RELAY]
分类和应用: 继电器光电二极管
文件页数/大小: 6 页 / 130 K
品牌: NAIS [ NAIS(MATSUSHITA ELECTRIC WORKS) ]
 浏览型号DS2E-SL2-DC5V的Datasheet PDF文件第2页浏览型号DS2E-SL2-DC5V的Datasheet PDF文件第3页浏览型号DS2E-SL2-DC5V的Datasheet PDF文件第4页浏览型号DS2E-SL2-DC5V的Datasheet PDF文件第5页浏览型号DS2E-SL2-DC5V的Datasheet PDF文件第6页  
TESTING
HIGHLY SENSITIVE 1500 V
FCC SURGE WITHSTANDING
MINIATURE RELAY
9.9
.390
9.8
.386
DS-RELAYS
FEATURES
• High sensitivity: 200 mW pick-up power
100 mW pick-up power types available
• Latching types available
• High switching capacity: 60 W, 125 V A
• High breakdown voltage: 1,500 V FCC surge between open contacts
1,000 V AC between open contacts
• DIP-1C type can be used with 14 pin IC socket
2C type can be used with 16 pin IC socket,
4C type can be used with 2 sets of 14 pin IC sockets
• Gold-cap silver palladium types available for 2 Form C type
• Bifurcated contacts are standard
35.24
1.387
20
.787
9.9
.390
9.8
.386
DS4E
15
.590
9.9
.390
9.8
.386
DS2E
DS1E
mm
inch
SPECIFICATIONS
Contact
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Contact material
Max. switching power
Rating
(resistive)
1 Form C, 2 Form C, 4 Form C
50 m
Gold-clad sliver
60 W, 125 VA
Characteristics (at 20
°
C
68
°
F)
Max. operating speed
Initial insuration resistance*
1
Type of relay
Initial
Between open contacts
break-
down volt- Between contacts sets
age*
2
Between contacts and coil
FCC surge voltage between contacts
and coil
Operate time*
3
(at nominal voltage)
Release time (without diode)* (at
nominal voltage)
Set time*
3
(at nominal voltage)
3
20 cpm at rated load
50 cps at low level load
Min. 100 M
(at 500 V DC)
(DS1-S type) (Other types)
500 Vrms
1,000 Vrms
1,000 Vrms
1,000 Vrms
1,500 Vrms
Expected
life (min.
operations)
Max. switching voltage
220 V DC, 250 V AC
Max. switching current
2 A DC, AC
Max. carrying current
3 A DC, AC
Mechanical
10
8
(at 600 cpm)
(1 Form C 2 coil latching type: 10
7
)
Electrical
5
×
10
5
2 A 30 VDC resistive
1,500 V (Expect DS1-S type)
Approx. 3 ms
Approx. 2 ms
Approx. 3 ms
Approx. 3 ms
Max. 65
°
C
1C, 2C:Min. 490 m/s
2
{50 G}
4C:Min. 294 m/s
2
{30 G}
Min. 980 m/s
2
{100 G}
10 to 55 Hz
at double amplitude of 3.3 mm
10 to 55 Hz
at double amplitude of 5 mm
–40
°
C to +70
°
C
–40
°
F to +158
°
F
5 to 85% R.H.
Approx. 3.2g
.11oz
Approx. 4g
.14oz
Approx. 7g
.25oz
* Gold capped silver-palladium contact also available for 2 Form C 10
7
operations at
0.1 A 50 V DC resistive
Coil (polarized) (at 20
°
C
68
°
F)
Single
side
stable
Minimum operating power
Nominal operating power
Reset time*
3
(at nominal voltage)
Temperature rise
(at nominal voltage, Contact current: 2A)
Shock resistance
Functional*
4
Destructive*
5
Functional*
6
Vibration resistance
Destructive
Approx. 200 mW
Approx. 400 mW
M 1 coil
Minimum set and reset power
Approx. 90 mW
type latching
Nominal set and reset power
Approx. 180 mW
Minimum set and reset power
Approx. 180 mW
2 coil
latching
Nominal set and reset power
Approx. 360 mW
Approx. 100 mW (128 mW)*
Single
Minimum operating power
side
Nominal operating power
Approx. 200 mW
stable
S 1 coil
Minimum set and reset power
Approx. 45 mW (58 mW)*
type latching
Nominal set and reset power
Approx. 90 mW
Minimum set and reset power
Approx. 90 mW (115 mW)*
2 coil
latching
Nominal set and reset power
Approx. 180 mW
* For 1 Form C high sensitive types.
FCC (Federal Communication Commission) re-
quests following standard as Breakdown Voltage
specification.
Conditions for operation,
transport and storage*
7
(Not freezing and condens-
ing at low temperature)
Unit weight
Remarks
Ambient
temp.
Humidity
1 Form C
2 Form C
4 Form C
1500V
750V
10
µs
160
µs
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as "Initial breakdown voltage" section
*
2
Detection current: 10 mA
*
3
Excluding contact bounce time
*
4
Half-wave pulse of sine wave: 11ms; detection time: 10
µ
s
*
5
Half-wave pulse of sine wave: 6ms
*
6
Detection time: 10
µ
s
*
7
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61)
186