DSP
SOCKETS FOR DSP RELAYS
TYPES AND APPLICABLE RELAYS
Type No.
Applicable relays
DSP1a relays
DSP1a-L2 relays
DSP1 relays
DSP1-L2 relays
DSP2a relays
DSP2a-L2 relays
For DSP1a
DSP1a-PS
DSP1a-PSL2
OK
OK
OK
For DSP1a, DSP1, DSP2a
DSP2a-PS
DSP2a-PSL2
OK
OK
OK
OK
OK
OK
OK
OK
OK
SPECIFICATIONS
Specifications
3,000 Vrms between
terminals
Breakdown voltage
(Except for the portion
between coil terminals)
1,000 MΩ between
Insulation resistance
terminals at 500 V
Heat resistance
150°C for 1 hour
Max. continuous
current
1a: 8 A
2a: 5 A
mm
inch
Item
DIMENSIONS
11
±0.6
.433
±
.024
23
±
0.6
.906
±
.024
8
5
2
15
PC board pattern (Copper-side view)
DSP1a-PS, DSP1a-PSL2
16
DSP2a-PS, DSP2a-PSL2
9
12
15
16
2.54
.100
1
8
5
2
1
2.54
.100
17
±0.6
.669
±.024
5.7
±
0.3
.224
±.012
3.7
.146
0.8
±
0.1
0.65
±
0.1
.031
±
.004
.026
±.004
2.54
±
0.3
.100
±
.012
7.62
±
0.3
7.62
±
0.3 10.16
±
0.3 2.61
.300
±
.012
.103
.300± .012 .400
±
.012
1.2 dia.
047 dia.
2.54
.100
1.2 dia.
047 dia.
2.54
.100
Terminal No.2 and 15 are for
DSP1a-PSL2 only.
Terminal No.2 and 15 are for
DSP2a-PSL2 only.
0.3
±
0.1
.012
±.004
FIXING AND REMOVAL METHOD
1. Match the direction of relay and socket.
3. Remove the relay, applying force in the
direction shown below.
2. Both ends of relays are fixed so surely
that the socket hooks on the top surface of
relays.
4. In case there is not enough space for
finger to pick relay up, use screw drivers in
the way shown below.
Good
No good
238