型号: LKS1AF-12V
PDF下载: 下载PDF文件 查看货源
内容描述: 250兆瓦的超薄功率继电器 [250 mW Slim Power Relay]
分类和应用: 继电器功率继电器
文件页数/大小: 3 页 / 48 K
品牌: NAIS [ NAIS(MATSUSHITA ELECTRIC WORKS) ]
 浏览型号LKS1AF-12V的Datasheet PDF文件第2页浏览型号LKS1AF-12V的Datasheet PDF文件第3页  
VDE
LK-S
250 mW Slim Power Relay
LK-S
RELAYS
3. High noise immunity realized by the
card separation structure between
contact and coil
4. Popular terminal pitch in AV equip-
ment field
5. Space-saving slim type
Base area: Width 11
×
Length 24 mm
Width .433
×
Length .945 inch
6. Conforms to the various safety stan-
dards
UL/CSA, VDE, TÜV and SEMKO SEV
approved
FEATURES
24.0
.945
11.0
.433
25.0
.984
mm
inch
1. High sensitivity: 250mW
The power-saving relay is highly sensitive
at the nominal operating power of 250
mW (530 mW power consumption on LK
relays).
2. High insulation resistance between
contact and coil
1) Creepage distance and clearances
between contact and coil: Min. 6 mm .236
inch
(In compliance with IEC65)
2) Surge withstand voltage between con-
tact and coil: 10,000 V or more
SPECIFICATIONS
Contact
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Contact material
Nominal switching capacity
Max. switching power
Rating
(resistive load)
Max. switching voltage
Max. switching current
Mechanical (at 180 cpm)
Electrical (at 20 cpm)
(at rated load)
1 Form A
Max. 100 m
Silver alloy
5 A 277 V AC
1,385 V A
277 V AC
5 A (AC)
10
6
10
5
Characteristics
Max. operating speed
Initial insulation resistance*
1
Initial *
2
breakdown
voltage
Between open
contacts
20 cpm (at rated load)
Min. 1,000 M
(at 500 V DC)
1,000 Vrms for 1 min.
4,000 Vrms for 1 min.
Min. 10,000 V
Approx. 7 ms (at 20
°
C
68
°
F)
Approx. 2 ms (at 20
°
C
68
°
F)
Max. 35
°
C with nominal coil
voltage and at 5 A contact
carrying current
(resistance method)
Min. 200 m/s
2
{approx. 20 G}
Min. 1,000 m/s
2
{approx. 100 G}
10 to 55Hz
at double amplitude of 1.5mm
10 to 55Hz
at double amplitude of 1.5mm
–40
°
C to +70
°
C
–40
°
F to +158
°
F
5 to 85% R.H.
86 to 106 kPa
Approx. 12 g
.42 oz
Between contact and
coil
Initial surge voltage between contact
and coil*
3
Operate time*
4
(at nominal voltage)
Release time (without diode)*
(at nominal voltage)
Temperature rise (at 70
°
C)
4
Expected life
(min. operations)
Coil
Nominal operating power
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as "Initial breakdown voltage" section.
*
2
Detection current: 10mA
*
3
Wave is standard shock voltage of
±
1.2
×
50
µ
s according to JEC-212-1981
*
4
Excluding contact bounce time.
*
5
Half-wave pulse of sine wave: 11 ms; detection time: 10
µ
s
*
6
Half-wave pulse of sine wave: 6 ms
*
7
Detection time: 10
µ
s
*
8
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 24).
250 mW
Shock resistance
Functional*
5
Destructive*
6
Functional*
7
Vibration resistance
Destructive
Conditions for operation,
transport and storage*
8
(Not freezing and con-
densing at low tempera-
ture)
Unit weight
Ambient
temp.
Humidity
Air
pressure
TYPICAL
APPLICATIONS
• Audio visual equipment
• Office equipment
• Home appliances
ORDERING INFORMATION
Ex. LKS
Contact arrangement
1a: 1 Form A
1a
F
12V
Coil voltage(DC)
5, 9, 12, 24V
Protective construction
F: Flux-resistant type
UL/CSA, TÜV, SEMKO, TV-5 approved type is standard.
Notes 1. Standard packing Carton: 100 pcs. Case: 500 pcs.
2. 6 V, 18 V DC types are also available. Please consult us for details.