PS2701-1,PS2701-2,PS2701-4
SPECIFICATION OF VDE MARKS LICENSE DOCUMENT (VDE0884)
Parameter
Application classification (DIN VDE 0109)
Symbol
Speck
Unit
for rated line voltages ≤ 300 Vr.m.s.
IV
III
for rated line voltages ≤ 600 Vr.m.s.
Climatic test class (DIN IEC 68 Teil 1/09.80)
Dielectric strength
55/100/21
Maximum operating isolation voltage
Test voltage (partial discharge test, procedure a for type test and random test)
Upr = 1.2 × UIORM, Pd < 5 pC
UIORM
Upr
710
850
Vpeak
Vpeak
Test voltage (partial discharge test, procedure b for random test)
Upr
1 140
Vpeak
Upr = 1.6 × UIORM, Pd < 5 pC
Highest permissible overvoltage
Degree of pollution (DIN VDE 0109)
Clearance distance
UTR
6 000
Vpeak
2
> 5
mm
mm
Creepage distance
> 5
Comparative tracking index (DIN IEC 112/VDE 0303 part 1)
Material group (DIN VDE 0109)
Storage temperature range
CTI
175
III a
Tstg
TA
–55 to +150
–55 to +100
°C
°C
Operating temperature range
Isolation resistance, minimum value
VIO = 500 V dc at TA = 25 °C
Ris MIN.
Ris MIN.
1012
1011
Ω
Ω
VIO = 500 V dc at TA MAX. at least 100 °C
Safety maximum ratings
(maximum permissible in case of fault, see thermal derating curve)
Package temperature
Tsi
Isi
150
200
300
°C
mA
mW
Current (input current IF, Psi = 0)
Power (output or total power dissipation)
Isolation resistance
Psi
VIO = 500 V dc at TA = 175 °C (Tsi)
Ris MIN.
109
Ω
9