PXI Chassis with Integrated MXI-Express Remote Controller  
Operating Environment  
Ambient temperature............................................................. 0 to 50 °C (tested in accordance with IEC-60068-2-1 and IEC-60068-2-2;  
meets MIL-PRF-28800F Class 3 low temperature limit and high temperature limit)  
Relative humidity................................................................... 20 to 80%, noncondensing (tested in accordance with IEC-60068-2-56)  
Storage Environment  
Ambient temperature............................................................. -40 to 85 °C (tested in accordance with IEC-60068-2-1 and IEC-60068-2-2;  
meets MIL-PRF-28800F Class 3 limits)  
Relative humidity................................................................... 10 to 95%, noncondensing (tested in accordance with IEC-60068-2-56)  
Backplane  
Size ....................................................................................... 3U-sized; integrated controller and 5 peripheral slots. Compliant with IEEE 1101.10  
mechanical packaging. Compliant with PXI Hardware Specification, Revision 2.2.  
Accepts both PXI and CompactPCI 3U modules.  
V(I/O)1..................................................................................... +5 V  
Backplane bare-board material ............................................. UL 94 V-0 recognized  
Backplane connectors............................................................ Conform to IEC 917 and IEC 1076-4-101, and are UL 94 V-0 rated  
1 V(I/O) is connected to the +5 V DC power plane, so the same specifications apply to V(I/O) and +5 V.  
10 MHz System Reference Clock (10 MHz REF)  
Maximum clock skew between slots.................................... 250 ps  
Built-in 10 MHz clock accuracy ............................................. 25 ppm (guaranteed over the operating temperature range)  
External clock source  
Connectors......................................................................... Slot 2 J2 (pin D17)  
Input frequency.................................................................. 10 MHz 100 ppm  
Input amplitude ................................................................. 5 or 3.3 V TTL signal  
Mechanical  
Overall dimensions (standard chassis)  
Height..................................................................................... 177 mm (6.97 in.)  
Note: 12.7 mm (0.50 in.) is added to height when feet are installed.  
Width ..................................................................................... 257.1 mm (10.12 in.)  
Depth...................................................................................... 212.8 mm (8.38 in.)  
Weight.................................................................................... 5 kg (11.0 lb)  
Chassis materials................................................................... Sheet aluminum, extruded aluminum, cold-rolled steel, nylon  
Finish...................................................................................... Clear chromate conversion coat on aluminum; electrodeposited nickel plate on steel,  
polyester urethane powder paint  
Shock and Vibration  
Operational shock.................................................................. 20 g peak, half-sine, 11 ms pulse (tested in accordance with IEC-60068-2-27;  
meets MIL-PRF-28800F Class 2 limits)  
Random Vibration  
Operating ............................................................................... 5 to 500 Hz, 0.3 grms  
Nonoperating ......................................................................... 5 to 500 Hz, 2.4 grms  
(tested in accordance with IEC-60068-2-64; nonoperating test profile exceeds the  
requirements of MIL-PRF-28800F, Class 3)  
Acoustic Emissions  
Sound Pressure Level (at operator’s position)  
PXI-1033  
Auto fan (at 25 °C ambient).............................................. 37.4 dBA  
High fan ............................................................................. 51.5 dBA  
(tested in accordance with ISO 7779; meets MIL-PRF-28800F requirements)  
BUY ONLINE at ni.com or CALL (800) 813 3693 (U.S.)  