Process Sealed Miniature Toggles
POLES & CIRCUITS
Toggle Position
( ) = Momentary
Pole
Model
M2T12
M2T13
M2T15
M2T18
M2T19
M2T22
M2T23
M2T25
M2T28
M2T29
Down
Center
Up
Connected Terminals
Down
Center
Up
Note:
Series M2
Throw & Schematics
Terminal numbers are not
actually on the switch.
SP
ON
ON
ON
(ON)
ON
ON
ON
ON
(ON)
ON
NONE
OFF
NONE
OFF
OFF
NONE
OFF
NONE
OFF
OFF
ON
ON
(ON)
(ON)
(ON)
ON
ON
(ON)
(ON)
(ON)
2 (COM)
2-3
OPEN
2-1
SPDT
3
1
2
(COM)
1
6
5
4
DP
2-3 5-6
OPEN
2-1 5-4
DPDT
3
ACTUATORS
S
.500” (12.7mm)
Bat Lever
(2.8) Dia
.110
(12.7)
.500
26°
S4
.300” (7.62mm)
Bat Lever
(2.7) Dia
.106
(7.62)
.300
26°
Material:
Chrome over brass
Material:
Chrome over brass
Standard Combinations:
S Bat Lever with straight terminals
(code 03) with silver or gold contacts.
Standard Combinations:
S4 Bat Lever with bracketed terminals
(codes 13, 30, 40) with silver or gold contacts.
BUSHING
A5
.250” (6.35mm) Double Flatted
(6.8)
.268
(6.2)
.244
(5.2)
.205
(6.35)
.250
CONTACT MATERIALS & RATINGS
W
G
Silver over Silver
Power Level
6A @ 125V AC & 3A @ 250V AC
Gold over Brass or Copper
Logic Level
0.4VA maximum @ 28V AC/DC maximum
Complete explanation of operating range in Supplement section.
A
Gold over Silver
Power Level
or Logic Level
6A @ 125V AC
or 0.4VA maximum @ 28V AC/DC maximum
Note: This dual rated option is suitable when two or more identical switches are used in logic and in power circuits
within the same application. See Supplement section for complete explanation of dual rating and operating range.
NKK Switches • email: sales@nkkswitches.com • Phone (480) 991-0942 • Fax (480) 998-1435 • www.nkkswitches.com
03-07