NTE3051
0.27” Polarity and Overflow
Numeric Display, Common Anode
Description:
The NTE3051 display is mounted on a lead–frame assembly which is then cast within a clear, electrically
non–conductive, transparent plastic compound.
Features:
D
0.27” High Characters
D
High Brightness
D
Low Power Requirements
D
Single–Plane Wide–Angle Visibility
D
Compatible with Most TTL and DTL Circuits
Absolute Raximum Ratings:
(Over Ambient Temperature Range unless otherwise specified)
Reverse Voltage (T
A
= +25°C), V
R
Each Segment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6V
Decimal Point . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3V
Peak Forward Current, each Segment or Decimal Point (Note 1), I
FP
. . . . . . . . . . . . . . . . . . . 200mA
Continuous Forward Current, I
F
Each Segment or Decimal Point . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30mA
Total Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150mA
Operating Ambient Temperature Range, T
A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0° to +70°C
Storage Temperature Range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –55° to +100°C
Note 1. This value applies for PRR
≥
60Hz, Duty Cycle
≤
10%.
Operating Characteristics:
(T
A
= +25°C unless otherwise specified)
Parameter
Luminous Intensity
Each Segment
Decimal Point
Wavelength at Peak Emission
Each Segment
Decimal Point
Spectral Bandwidth between Half Points
B
I
F
= 20mA
λ
P
I
F
= 20mA
Symbol
I
V
Test Conditions
I
F
= 20mA, Note 2
Min
100
40
640
645
–
Typ
275
110
660
665
20
Max
–
–
680
685
–
Unit
µcd
µcd
nm
nm
nm
Note 2. Luminous intensity is measured with a solar cell and filter combination which approximates
the CIE (International Commission on Illumination) eye–response curve.