Maximum Ratings and Electrical Characteristics (Cont’d):
(T
C
= +25°C, unless otherwise specified.
Single phase, half wave, 60Hz, resistive or inductive load, for capacitive load, derate current by 20%)
Maximum Dynamic
Zener
Impedance
Test
Nominal
Zener Voltage Current
Z
zt
@ I
zt
Z
zk
@ I
zk
V
z
@ I
zt
(I
zt
)
Volts
mA
Ω
Ω
mA
87
91
100
110
120
130
140
150
160
170
180
190
200
2.9
2.8
2.5
2.3
2.1
1.9
1.8
1.7
1.6
1.5
1.4
1.3
1.3
225
250
350
600
700
800
900
1000
1100
1200
1300
1400
1500
3000
3000
3000
5000
5000
5000
5000
5000
5000
5000
5000
5000
5000
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
Maximum
Leakage
Current
I
R
@ V
R
µA
Volts
5
5
5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
65.7
69.2
76.0
80
90
95
105
110
120
130
140
150
160
Max DC
Zener Max Forward
Current
Voltage
(I
zm
)
V
F
@ I
F
mA
Volts
mA
–
–
–
9.1
8.3
7.7
7.1
6.6
6.3
5.9
5.6
5.3
5.0
1.2
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
200
200
200
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
NTE Type
Number
NTE5094A
NTE5095A
NTE5096A
NTE151A
NTE5097A
NTE5098A
NTE5099A
NTE5100A
NTE5101A
NTE5102A
NTE5103A
NTE5104A
NTE5105A
1.100
(27.94)
Min
.210
(5.33)
Max
.034 (0.87) Dia Max
Color Band Denotes Cathode
.107 (2.72)
Dia Max