Electrical Characteristics:
(T
A
= +25°C unless otherwise specified)
Parameter
Dynamic Characteristics
Amplifier No. 1 Voltage Gain
Amplifier No. 2 Voltage Gain
Maximum Chroma Output Voltage
10% Chroma Gain Control Reference Voltage
A
V1
A
V2
V
9
V
8
–V
10
E
g
= 50mV
rms
, adjust Chroma
Gain Control to Change V
g
to
10% of Maximum Chroma
Output
V
9
S
1
in Position 2, E
g
= 50mV
RMS
,
adjust “Killer Adjust” for an
abrupt decrease in V
9
E
g
= 50mV
RMS
, adjust Chroma
control to min. Chroma Output
E
g
= 30mV
RMS
Measure V
6
V
g
= 1.0V(RMS) Measure V
7
14
–
–
2.1
–
14
2
3.8
–
–
–
6.8
dB
dB
V
RMS
V
Symbol
Test Conditions
Min
Typ
Max
Unit
Output Voltage, Killer Off
–
–
12
mV
RMS
Output Voltage, Chroma
Bandwidth
Amplifier No. 1
Amplifier No. 2
Amplifier No. 1 Input Impedance
Amplifier No. 1 Input Capacitance
Amplifier No. 1 Output Impedance
Ampl. No. 2 Input Impedance
Ampl. No. 2 Output Impedance
V
9
–
–
12
mV
RMS
BW
r
I
1
c
i
1
r
o
1
r
i
2
r
o
2
–
–
–
–
–
–
–
12
30
2
4
85
2.1
85
–
–
–
–
–
–
–
MHz
MHz
kΩ
pF
Ω
kΩ
Ω
Pin Connection Diagram
14
8
ACC Input
1
Chroma 1 Input
2
Gain Preselect
3
GND
4
N.C.
5
Chroma 1 Output
6
Chroma 2 Input
7
14
ACC Input
13
Killer Adjust
12
Decouple
11
Decouple
10
Chroma Level Control
9
Chroma 2 Output
8
V
CC
1
.785 (19.95)
Max
7
.300
(7.62)
.200 (5.08)
Max
.100 (2.45)
.600
(15.24)
.099 (2.5) Min