DC and AC parameters
Table 15.
AC characteristics (grade 6,
T9HX technology
)
M25P16
Applies only to products made with T9HX technology, identified with process digit ‘4’
(1)
Test conditions specified in
and
Symbol Alt.
Parameter
Clock frequency for the following instructions:
FAST_READ, PP, SE, BE, DP, RES, WREN,
WRDI, RDID, RDSR, WRSR
Clock frequency for READ instructions
t
CLH
Clock High time
t
CLL
Clock Low time
Clock Rise time
(5)
(peak to peak)
Clock Fall time
(5)
(peak to peak)
t
CSS
S Active Setup time (relative to C)
S Not Active Hold time (relative to C)
t
DSU
Data In Setup time
t
DH
Data In Hold time
S Active Hold time (relative to C)
S Not Active Setup time (relative to C)
t
CSH
S Deselect time
Min
Typ
(2)
Max
Unit
f
C
f
R
t
CH(3)
t
CL(2)
t
CLCH(4)
t
CHCL(4)
t
SLCH
t
CHSL
t
DVCH
t
CHDX
t
CHSH
t
SHCH
t
SHSL
f
C
D.C.
D.C.
6
6
0.1
0.1
5
5
2
5
5
5
100
75
33
MHz
MHz
ns
ns
V/ns
V/ns
ns
ns
ns
ns
ns
ns
ns
t
SHQZ(4)
t
DIS
Output Disable time
t
CLQV
t
CLQX
t
HLCH
t
CHHH
t
HHCH
t
CHHL
t
HHQX(4)
t
HLQZ(4)
t
WHSL(6)
t
SHWL(6)
t
DP(4)
t
RES1(4)
t
RES2(4)
t
W
t
V
Clock Low to Output Valid under 30 pF/10 pF
0
5
5
5
5
8
8/6
ns
ns
ns
ns
ns
ns
ns
t
HO
Output Hold time
HOLD Setup time (relative to C)
HOLD Hold time (relative to C)
HOLD Setup time (relative to C)
HOLD Hold time (relative to C)
t
LZ
HOLD to Output Low-Z
t
HZ
HOLD to Output High-Z
Write Protect Setup time
Write Protect Hold time
S High to Deep Power-down mode
S High to Standby mode without Read
Electronic Signature
S High to Standby mode with Read Electronic
Signature
Write Status Register cycle time
8
8
20
100
3
30
30
1.3
15
ns
ns
ns
ns
µs
µs
µs
ms
40/55