DC and AC parameters
M25P20
10
DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC Characteristic tables that
follow are derived from tests performed under the Measurement Conditions summarized in
the relevant tables. Designers should check that the operating conditions in their circuit
match the measurement conditions when relying on the quoted parameters.
Table 10.
Symbol
V
CC
T
A
Supply Voltage
Ambient Operating Temperature (Device Grade 6)
Ambient Operating Temperature (Device Grade 3)
Operating Conditions
Parameter
Min.
2.7
–40
–40
Max.
3.6
85
°C
125
Unit
V
Table 11.
Data Retention and Endurance
Condition
Device Grade 6
Device Grade 3
at 55°C
Min.
Max.
100,000
10,000
20
Unit
cycles per
sector
years
Parameter
Erase/Program
Cycles
Data Retention
Table 12.
Symbol
C
OUT
C
IN
Capacitance
Parameter
Output Capacitance (Q)
Input Capacitance (other pins)
Test Condition
V
OUT
= 0V
V
IN
= 0V
Min.
Max.
8
6
Unit
pF
pF
1. Sampled only, not 100% tested, at T
A
=25°C and a frequency of 20MHz.
36/50