M28W160ECT, M28W160ECB
Table 14. DC Characteristics
Symbol
I
LI
I
LO
I
DD
I
DD1
I
DD2
Parameter
Input Leakage Current
Output Leakage Current
Supply Current (Read)
Supply Current (Stand-by or
Automatic Stand-by)
Supply Current
(Reset)
Test Condition
0V≤V
IN
≤
V
DDQ
0V
≤
V
OUT
≤
DDQ
V
E = V
SS
, G = V
IH
, f = 5MHz
E = V
DDQ
± 0.2V,
RP = V
DDQ
± 0.2V
RP = V
SS
± 0.2V
Program in progress
V
PP
= 12V ± 5%
Program in progress
V
PP
= V
DD
Erase in progress
V
PP
= 12V ± 5%
Erase in progress
V
PP
= V
DD
E = V
DDQ
± 0.2V,
Erase suspended
V
PP
> V
DD
V
PP
≤
V
DD
RP = V
SS
± 0.2V
Program in progress
V
PP
= 12V ± 5%
Program in progress
V
PP
= V
DD
Erase in progress
V
PP
= 12V ± 5%
Erase in progress
V
PP
= V
DD
–0.5
V
DDQ
≥
2.7V
V
DDQ
≥
2.7V
I
OL
= 100µA, V
DD
= V
DD
min,
V
DDQ
= V
DDQ
min
I
OH
= –100µA, V
DD
= V
DD
min,
V
DDQ
= V
DDQ
min
V
DDQ
–0.1
1.65
11.4
3.6
12.6
1
2
–0.5
V
DDQ
–0.4
0.7 V
DDQ
1
1
1
1
3
1
9
15
15
5
10
5
10
15
Min
Typ
Max
±1
±10
18
50
50
10
20
20
20
50
400
5
5
10
5
10
5
0.4
0.8
V
DDQ
+0.4
V
DDQ
+0.4
0.1
Unit
µA
µA
mA
µA
µA
mA
mA
mA
mA
µA
µA
µA
µA
mA
µA
mA
µA
V
V
V
V
V
V
V
V
V
V
I
DD3
Supply Current (Program)
I
DD4
Supply Current (Erase)
I
DD5
I
PP
I
PP1
I
PP2
Supply Current
(Program/Erase Suspend)
Program Current
(Read or Stand-by)
Program Current
(Read or Stand-by)
Program Current (Reset)
I
PP3
Program Current (Program)
I
PP4
Program Current (Erase)
V
IL
V
IH
V
OL
V
OH
V
PP1
V
PPH
V
PPLK
V
LKO
Input Low Voltage
Input High Voltage
Output Low Voltage
Output High Voltage
Program Voltage (Program or
Erase operations)
Program Voltage
(Program or Erase
operations)
Program Voltage
(Program and Erase lock-out)
V
DD
Supply Voltage (Program
and Erase lock-out)
22/50