DC and AC parameters
M29W128FH, M29W128FL
M29W128FH,
Table 21. Read AC characteristics
M29W128FL
Symbol
Alt
Parameter
Test condition
Unit
60
70
E = VIL,
G = VIL
tAVAV
tAVQV
tAVQV1
tRC Address Valid to Next Address Valid
tACC Address Valid to Output Valid
Min
60
70
ns
ns
ns
E = VIL,
G = VIL
Max
Max
60
25
70
30
E = VIL,
G = VIL
tPAGE Address Valid to Output Valid (Page)
(1)
tELQX
tLZ
Chip Enable Low to Output Transition
G = VIL
G = VIL
E = VIL
E = VIL
G = VIL
E = VIL
Min
Max
Min
0
0
ns
ns
ns
ns
ns
ns
tELQV
tCE Chip Enable Low to Output Valid
tOLZ Output Enable Low to Output Transition
tOE Output Enable Low to Output Valid
tHZ Chip Enable High to Output Hi-Z
tDF Output Enable High to Output Hi-Z
60
0
70
0
(1)
tGLQX
tGLQV
Max
Max
Max
20
25
25
25
25
25
(1)
tEHQZ
(1)
tGHQZ
tEHQX
tGHQX
Chip Enable, Output Enable or Address
Transition to Output Transition
tOH
Min
0
5
0
5
ns
ns
tAXQX
tELBL
tELBH
tBLQZ
tBHQV
tELFL
Chip Enable to BYTE Low or High
tELFH
Max
tFLQZ BYTE Low to Output Hi-Z
tFHQV BYTE High to Output Valid
Max
Max
25
30
25
30
ns
ns
1. Sampled only, not 100% tested.
46/78