欢迎访问ic37.com |
会员登录 免费注册
发布采购

M29W320DB70ZE6T 参数 Datasheet PDF下载

M29W320DB70ZE6T图片预览
型号: M29W320DB70ZE6T
PDF下载: 下载PDF文件 查看货源
内容描述: 32兆位( 4Mbx8或2Mbx16 ,非均匀参数块,引导块) 3V供应闪存 [32 Mbit (4Mbx8 or 2Mbx16, Non-uniform Parameter Blocks, Boot Block), 3V Supply Flash memory]
分类和应用: 闪存存储内存集成电路
文件页数/大小: 56 页 / 1058 K
品牌: NUMONYX [ NUMONYX B.V ]
 浏览型号M29W320DB70ZE6T的Datasheet PDF文件第14页浏览型号M29W320DB70ZE6T的Datasheet PDF文件第15页浏览型号M29W320DB70ZE6T的Datasheet PDF文件第16页浏览型号M29W320DB70ZE6T的Datasheet PDF文件第17页浏览型号M29W320DB70ZE6T的Datasheet PDF文件第19页浏览型号M29W320DB70ZE6T的Datasheet PDF文件第20页浏览型号M29W320DB70ZE6T的Datasheet PDF文件第21页浏览型号M29W320DB70ZE6T的Datasheet PDF文件第22页  
Command Interface
M29W320DT, M29W320DB
4.3
Read CFI Query command
The Read CFI Query Command is used to read data from the Common Flash Interface
(CFI) Memory Area. This command is valid when the device is in the Read Array mode, or
when the device is in Autoselected mode.
One Bus Write cycle is required to issue the Read CFI Query Command. Once the
command is issued subsequent Bus Read operations read from the Common Flash
Interface Memory Area.
The Read/Reset command must be issued to return the device to the previous mode (the
Read Array mode or Autoselected mode). A second Read/Reset command would be
needed if the device is to be put in the Read Array mode from Autoselected mode.
See
and
for details on the information contained in the Common Flash
Interface (CFI) memory area.
4.4
Program command
The Program command can be used to program a value to one address in the memory array
at a time. The command requires four Bus Write operations, the final write operation latches
the address and data in the internal state machine and starts the Program/Erase Controller.
If the address falls in a protected block then the Program command is ignored, the data
remains unchanged. The Status Register is never read and no error condition is given.
During the program operation the memory will ignore all commands. It is not possible to
issue any command to abort or pause the operation. Typical program times are given in
Bus Read operations during the program operation will output the Status Register
on the Data Inputs/Outputs. See the section on the Status Register for more details.
After the program operation has completed the memory will return to the Read mode, unless
an error has occurred. When an error occurs the memory will continue to output the Status
Register. A Read/Reset command must be issued to reset the error condition and return to
Read mode.
Note that the Program command cannot change a bit set at ’0’ back to ’1’. One of the Erase
Commands must be used to set all the bits in a block or in the whole memory from ’0’ to ’1’.
4.5
Unlock Bypass command
The Unlock Bypass command is used in conjunction with the Unlock Bypass Program
command to program the memory. When the cycle time to the device is long (as with some
EPROM programmers) considerable time saving can be made by using these commands.
Three Bus Write operations are required to issue the Unlock Bypass command.
Once the Unlock Bypass command has been issued the memory will only accept the Unlock
Bypass Program command and the Unlock Bypass Reset command. The memory can be
read as if in Read mode.
The memory offers accelerated program operations through the V
PP
/Write Protect pin.
When the system asserts V
PP
on the V
PP
/Write Protect pin, the memory automatically
enters the Unlock Bypass mode. The system may then write the two-cycle Unlock Bypass
18/56