欢迎访问ic37.com |
会员登录 免费注册
发布采购

M29W320EB90ZE6 参数 Datasheet PDF下载

M29W320EB90ZE6图片预览
型号: M29W320EB90ZE6
PDF下载: 下载PDF文件 查看货源
内容描述: 32兆位( 4Mbx8或2Mbx16 ,统一参数块,引导块) 3V供应闪存 [32 Mbit (4Mbx8 or 2Mbx16, Uniform Parameter Blocks, Boot Block) 3V supply Flash memory]
分类和应用: 闪存
文件页数/大小: 63 页 / 1191 K
品牌: NUMONYX [ NUMONYX B.V ]
 浏览型号M29W320EB90ZE6的Datasheet PDF文件第17页浏览型号M29W320EB90ZE6的Datasheet PDF文件第18页浏览型号M29W320EB90ZE6的Datasheet PDF文件第19页浏览型号M29W320EB90ZE6的Datasheet PDF文件第20页浏览型号M29W320EB90ZE6的Datasheet PDF文件第22页浏览型号M29W320EB90ZE6的Datasheet PDF文件第23页浏览型号M29W320EB90ZE6的Datasheet PDF文件第24页浏览型号M29W320EB90ZE6的Datasheet PDF文件第25页  
M29W320ET, M29W320EB
Command interface
4.3
Read CFI Query command
The Read CFI Query Command is used to read data from the Common Flash Interface
(CFI) memory Area. This command is valid when the device is in the Read Array mode, or
when the device is in Auto Select mode.
One Bus Write cycle is required to issue the Read CFI Query Command. Once the
command is issued subsequent Bus Read operations read from the Common Flash
Interface memory Area.
The Read/Reset command must be issued to return the device to the previous mode (the
Read Array mode or Auto Select mode). A second Read/Reset command would be needed
if the device is to be put in the Read Array mode from Auto Select mode.
See
and
for details on the information contained in the Common Flash
Interface (CFI) memory area.
4.4
Program command
The Program command can be used to program a value to one address in the memory array
at a time. The command requires four Bus Write operations, the final write operation latches
the address and data, and starts the Program/Erase Controller.
If the address falls in a protected block then the Program command is ignored, the data
remains unchanged. The Status register is never read and no error condition is given.
During the program operation the memory will ignore all commands. It is not possible to
issue any command to abort or pause the operation. After programming has started, Bus
Read operations output the Status register content. See
for more
details. Typical program times are given in
After the program operation has completed the memory will return to the Read mode, unless
an error has occurred. When an error occurs Bus Read operations will continue to output
the Status register. A Read/Reset command must be issued to reset the error condition and
return to Read mode.
Note that the Program command cannot change a bit set at ’0’ back to ’1’. One of the Erase
Commands must be used to set all the bits in a block or in the whole memory from ’0’ to ’1’.
21/63