 浏览型号M29W640GL70NB6F的Datasheet PDF文件第21页浏览型号M29W640GL70NB6F的Datasheet PDF文件第22页浏览型号M29W640GL70NB6F的Datasheet PDF文件第23页浏览型号M29W640GL70NB6F的Datasheet PDF文件第24页浏览型号M29W640GL70NB6F的Datasheet PDF文件第26页浏览型号M29W640GL70NB6F的Datasheet PDF文件第27页浏览型号M29W640GL70NB6F的Datasheet PDF文件第28页浏览型号M29W640GL70NB6F的Datasheet PDF文件第29页  
M29W640GH, M29W640GL, M29W640GT, M29W640GB
Command Interface
4.1.5
Block Erase command
The Block Erase command can be used to erase a list of one or more blocks. Six Bus Write
operations are required to select the first block in the list. Each additional block in the list can
be selected by repeating the sixth Bus Write operation using the address of the additional
block. The Block Erase operation starts the Program/Erase Controller about 50µs after the
last Bus Write operation. Once the Program/Erase Controller starts it is not possible to
select any more blocks. Each additional block must therefore be selected within 50µs of the
last block. The 50µs timer restarts when an additional block is selected. The Status Register
can be read after the sixth Bus Write operation. See the Status Register section for details
on how to identify if the Program/Erase Controller has started the Block Erase operation.
If any selected blocks are protected then these are ignored and all the other selected blocks
are erased. If all of the selected blocks are protected the Block Erase operation appears to
start but will terminate within about 100µs, leaving the data unchanged. No error condition is
given when protected blocks are ignored.
During the Block Erase operation the memory will ignore all commands except the Erase
Suspend command. Typical block erase times are given in
All Bus Read operations during the Block Erase operation will output
the Status Register on the Data Inputs/Outputs. See the section on the Status Register for
more details.
After the Block Erase operation has completed the memory will return to the Read Mode,
unless an error has occurred. When an error occurs the memory will continue to output the
Status Register. A Read/Reset command must be issued to reset the error condition and
return to Read mode.
The Block Erase Command sets all of the bits in the unprotected selected blocks to ’1’. All
previous data in the selected blocks is lost.
Refer to
for a description of Block Erase
ac waveforms.
4.1.6
Erase Suspend command
The Erase Suspend Command may be used to temporarily suspend a Block Erase
operation and return the memory to Read mode. The command requires one Bus Write
operation.
The Program/Erase Controller will suspend within the Erase Suspend Latency time of the
Erase Suspend Command being issued. Once the Program/Erase Controller has stopped
the memory will be set to Read mode and the Erase will be suspended. If the Erase
Suspend command is issued during the period when the memory is waiting for an additional
block (before the Program/Erase Controller starts) then the Erase is suspended immediately
and will start immediately when the Erase Resume Command is issued. It is not possible to
select any further blocks to erase after the Erase Resume.
During Erase Suspend it is possible to Read and Program cells in blocks that are not being
erased; both Read and Program operations behave as normal on these blocks. If any
attempt is made to program in a protected block or in the suspended block then the Program
command is ignored and the data remains unchanged. The Status Register is not read and
no error condition is given. Reading from blocks that are being erased will output the Status
Register.