DC and ac parameters
M29W640GH, M29W640GL, M29W640GT, M29W640GB
7
DC and ac parameters
This section summarizes the operating and measurement conditions, and the dc and ac
characteristics of the device. The parameters in the dc and ac Characteristic tables that
follow are derived from tests performed under the Measurement Conditions summarized in
the relevant tables. Designers should check that the operating conditions in their circuit
match the measurement conditions when relying on the quoted parameters.
Table 15.
Operating and ac measurement conditions
Parameter
M29W640GT, M29W640GB,
M29W640GH, M29W640GL
Min
V
CC
Supply Voltage
Ambient Operating Temperature
Load Capacitance (C
L
)
Input Rise and Fall Times
Input Pulse Voltages
Input and Output Timing Ref. Voltages
0 to V
CC
V
CC
/2
2.7
–40
30
10
Max
3.6
85
V
°C
pF
ns
V
V
Unit
Figure 11. AC measurement I/O waveform
VCC
VCC/2
0V
AI05557
Figure 12. AC measurement load circuit
VPP
VCC
VCC
25kΩ
DEVICE
UNDER
TEST
25kΩ
CL
0.1µF
0.1µF
CL includes JIG capacitance
AI05558
46/90