 浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第23页浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第24页浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第25页浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第26页浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第28页浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第29页浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第30页浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第31页  
M58LT128HST, M58LT128HSB
Command interface
4.12
Program/Erase Resume command
The Program/Erase Resume command is used to restart the Program or Erase operation
suspended by the Program/Erase Suspend command. One Bus Write cycle is required to
issue the command. The command can be issued to any address.
The Program/Erase Resume command does not change the Read mode of the banks. If the
suspended bank was in Read Status Register, Read Electronic signature, or Read CFI
Query mode, the bank remains in that mode and outputs the corresponding data.
If a Program command is issued during a Block Erase Suspend, then the erase cannot be
resumed until the program operation has completed.
See
and
for flowcharts for using the
Program/Erase Resume command.
4.13
Protection Register Program command
The Protection Register Program command is used to program the user segments of the
Protection Register and the two Protection Register Locks.
The device features 16 OTP segments of 128 bits and one OTP segment of 64 bits, as
shown in
The segments are programmed one word at a time. When shipped, all bits in the segment
are set to ‘1’. The user can only program the bits to ‘0’.
The following two Bus Write cycles are required to issue the Protection Register Program
command:
The first bus cycle sets up the Protection Register Program command.
The second latches the address and data to be programmed to the Protection Register
and starts the Program/Erase Controller.
Read operations to the bank being programmed output the Status Register content after the
Program operation has started. Attempting to program a previously protected Protection
Register results in a Status Register error.
The Protection Register Program cannot be suspended. Dual operations between the
Parameter Bank and the Protection Register memory space are not allowed (see
for details).
The two Protection Register Locks are used to protect the OTP segments from further
modification. The protection of the OTP segments is not reversible. Refer to
and
for details on the
Lock bits.
See
for a
flowchart for using the Protection Register Program command.
27/110