欢迎访问ic37.com |
会员登录 免费注册
发布采购

M58LT256JST8ZA6 参数 Datasheet PDF下载

M58LT256JST8ZA6图片预览
型号: M58LT256JST8ZA6
PDF下载: 下载PDF文件 查看货源
内容描述: 256兆位( Mb的16 】 16 ,多银行,多层次,突发) 1.8 V电源供电,安全闪存 [256 Mbit (16 Mb 】 16, multiple bank, multilevel, burst) 1.8 V supply, secure Flash memories]
分类和应用: 闪存存储内存集成电路
文件页数/大小: 108 页 / 1965 K
品牌: NUMONYX [ NUMONYX B.V ]
 浏览型号M58LT256JST8ZA6的Datasheet PDF文件第17页浏览型号M58LT256JST8ZA6的Datasheet PDF文件第18页浏览型号M58LT256JST8ZA6的Datasheet PDF文件第19页浏览型号M58LT256JST8ZA6的Datasheet PDF文件第20页浏览型号M58LT256JST8ZA6的Datasheet PDF文件第22页浏览型号M58LT256JST8ZA6的Datasheet PDF文件第23页浏览型号M58LT256JST8ZA6的Datasheet PDF文件第24页浏览型号M58LT256JST8ZA6的Datasheet PDF文件第25页  
M58LT256JST, M58LT256JSB
Command interface
4.5
Clear Status Register command
The Clear Status Register command resets (set to ‘0’) all error bits (SR1, 3, 4 and 5) in the
Status Register.
One bus write cycle is required to issue the Clear Status Register command. The Clear
Status Register command does not affect the read mode of the bank.
The error bits in the Status Register do not automatically return to ‘0’ when a new command
is issued. The error bits in the Status Register should be cleared before attempting a new
program or erase command.
4.6
Block Erase command
The Block Erase command erases a block. It sets all the bits within the selected block to ’1’
and all previous data in the block is lost.
If the block is protected, then the erase operation aborts, the data in the block is not
changed, and the Status Register outputs the error.
Two bus write cycles are required to issue the command.
The first bus cycle sets up the Block Erase command.
The second latches the block address and starts the Program/Erase Controller.
If the second bus cycle is not the Block Erase Confirm code, Status Register bits SR4 and
SR5 are set, and the command is aborted.
Once the command is issued, the bank enters read Status Register mode and any read
operation within the addressed bank outputs the contents of the Status Register. A Read
Array command is required to return the bank to read array mode.
During block erase operations the bank containing the block being erased only accepts the
Read Array, Read Status Register, Read Electronic Signature, Read CFI Query and the
Program/Erase Suspend commands, and all other commands are ignored.
The block erase operation aborts if Reset, RP, goes to V
IL
. As data integrity cannot be
guaranteed when the Block Erase operation is aborted, the block must be erased again.
Refer to
for detailed information about simultaneous operations allowed in banks
not being erased.
Typical erase times are given in
,
.
See
for a suggested
flowchart for using the Block Erase command.
21/108