欢迎访问ic37.com |
会员登录 免费注册
发布采购

MSM51V4221C-40RD 参数 Datasheet PDF下载

MSM51V4221C-40RD图片预览
型号: MSM51V4221C-40RD
PDF下载: 下载PDF文件 查看货源
内容描述: 262263字× 4位字段存储 [262,263-Word 】 4-Bit Field Memory]
分类和应用: 存储
文件页数/大小: 16 页 / 233 K
品牌: OKI [ OKI ELECTRONIC COMPONETS ]
 浏览型号MSM51V4221C-40RD的Datasheet PDF文件第3页浏览型号MSM51V4221C-40RD的Datasheet PDF文件第4页浏览型号MSM51V4221C-40RD的Datasheet PDF文件第5页浏览型号MSM51V4221C-40RD的Datasheet PDF文件第6页浏览型号MSM51V4221C-40RD的Datasheet PDF文件第8页浏览型号MSM51V4221C-40RD的Datasheet PDF文件第9页浏览型号MSM51V4221C-40RD的Datasheet PDF文件第10页浏览型号MSM51V4221C-40RD的Datasheet PDF文件第11页  
FEDS51V4221C-03
Semiconductor
1
MSM51V4221C
Power-up and Initialization
On power-up, the device is designed to begin proper operation after at least 100
µs
after V
CC
has stabilized to a
value within the range of recommended operating conditions. After this 100
µs
stabilization interval, the following
initialization sequence must be performed.
Because the read and write address counters are not valid after power-up, a minimum of 130 dummy write
operations (SWCK cycles) and read operations (SRCK cycles) must be performed, followed by an RSTW
operation and an RSTR operation, to properly initialize the write and the read address pointer. Dummy write
cycles/RSTW and dummy read cycles/RSTR may occur simultaneously.
If these dummy read and write operations start while V
CC
and/or the substrate voltage has not stabilized, it is
necessary to perform an RSTR operation plus a minimum of 130 SRCK cycles plus another RSTR operation, and
an RSTW operation plus a minimum of 130 SRCK cycles plus another RSTW operation to properly initialize read
and write address pointers.
Old/New Data Access
There must be a minimum delay of 600 SWCK cycles between writing into memory and reading out from memory.
If reading from the first field starts with an RSTR operation, before the start of writing the second field (before the
next RSTW operation), then the data just written will be read out.
The start of reading out the first field of data may be delayed past the beginning of writing in the second field of
data for as many as 119 SWCK cycles. If the RSTR operation for the first field read-out occurs less than 119
SWCK cycles after the RSTW operation for the second field write-in, then the internal buffering of the device
assures that the first field will still be read out. The first field of data that is read out while the second field of data
is written is called “old data”.
In order to read out “new data”, i.e., the second field written in, the delay between an RSTW operation and an
RSTR operation must be at least 600 SRCK cycles. If the delay between RSTW and RSTR operations is more than
120 but less than 600 cycles, then the data read out will be undetermined. It may be “old data” or “new” data, or a
combination of old and new data. Such a timing should be avoided.
7/16