Rating/Performance
Item
Sensing distance
adjustable range
Sensing object
Differential distance
Response frequency
Model
E2K-C25M#1
25 mm
3 to 25 mm
Conductors and dielectrics
15% max. of sensing distance (when adjusted to 25 mm ±10% with standard object)
70 Hz
10 Hz
E2K-C25M#2
E2K-C25MY1
E2K-C25MY2
Sensing distance *
Standard sensing object with grounded metal: 50 x 50 x 1t mm
Power supply(Operating
12 to 24 VDC, ripple (p-p): 10% max.,(10 to 40 VDC) 100 to 220 VAC (90 to 250 VAC) 50/60 Hz
voltage range)
Current consumption
Leakage current
Switching
capacity
Residual
voltage
E models: 10 mA max. at 12 VDC, 16 mA max. at 24 VDC
Y models: 1 mA max. at 100 VAC (50/60 Hz) with output turned OFF., 2 mA max. at 200 VAC (50/60 Hz)
with output turned OFF.
200 mA max.
5 to 200 mA (resistive load)
Control
output
2 V max. (under load current of 200 mA with cable length of 2 m)
Detection indicator (red LED)
E1, Y1 models: NO
E2, Y2 models: NC
Reverse connection protection, surge absorber
Surge absorber
Operation indicator (red LED)
Indicator lamp
Operating status
(with sensing object
approaching)
Protective circuits
Ambient temperature
Ambient humidity
Temperature influence
Operating/Storage: -25°C to 70°C (with no icing or condensation)
Operating/Storage: 35% to 95%RH (with no condensation)
±15%max. of sensing distance at 23° within temperature range -10°C to 55°C
±2% max. of sensing distance at a voltage between
85% and 115% of the rated power supply voltage
±2% max. sensing distance at a voltage ranging from
90% to 120% of a rated power voltage of 100 VAC
and from 80% to 120% of a rated supply voltage of
200 VAC
1,500 VAC 50/60 Hz for 1min between energized part
and case
E2K-C
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Protective structure
Connection method
Weight (Packed state)
Case
Material
Sensing
surface
50 MW min. (at 500 VDC) between current carry parts and case
1000 VAC 50/60 Hz for 1 min
between energized part and case
10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 500 m/s
2
for 10 times each in X, Y, and Z directions
IEC 60529 IP66
Pre-wired models (standard length: 2 m)
Approx. 200 g
Heat-resistant ABS resin
Mounting bracket, instruction manual
Accessories
* The set distances are sensing distances applicable to standard sensing objects. Refer to Engineering Data for sensing distances applicable to other types of objects.
E2K-C
E-75