Characteristics
Contact resistance
Operate time
Release time
Bounce Time
Max. switching frequency
Insulation resistance
Dielectric strength
100 mΩ max.
10 ms max.
5 ms max.
Operate: Approx. 0.6ms
Release: Approx. 7.2ms
Mechanical:
Electrical:
18,000 operations/hr
1,800 operations/hr at rated load
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min between coil and contacts
750 VAC, 50/60 Hz for 1 min between contacts of same polarity
1,500 VAC (for suffix -G) 50/60Hz for 1 min between contacts of same polarity
4,500 V (1.2 x 50
μs)
between coil and contacts
Impulse withstand voltage
Insulation
Distance
Creepage (Typ)
3.3 mm
Clearance (Typ)
2.7 mm
250 V
Destruction:
Malfunction:
Destruction:
Malfunction:
Mechanical:
Electrical:
10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
1,000 m/s
2
100 m/s
2
10,000,000 operations min. (at 18,000 operations/hr)
100,000 operations min. (at 1,800 operations/hr) for standard type
36,000 operations min. (10A at 250VAC)
100,000 operations min. (at 1,800 operations/hr), 12A 250 VAC) - applicable for
G5LE-1-E,NO contact only
Tracking Resistance (CTI)
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
Operating:
−25°C
to 85°C (with no icing)
Operating: 5% to 85%
Approx. 12 g
■
Approved Standards
UL Recognized (File No. E41643)
CSA Certified (File No. LR34815)
Model
G5LE
Coil rating
3 to 48 VDC
(Standard)
5 to 24 VDC
(-E versions)
9 to 24 VDC
(-G versions)
Contact rating
10 A, 250 VAC (general use), 6,000 cycles, 40°C (excluding -G type)
10 A, 125 VAC (general use), 100,000 cycles, 40°C (excluding -E, -G types)
8 A, 30 VDC (resistive load), 6,000 cycles, 40°C (excluding -E, -G types)
125 VA, 125 VAC, pilot duty, 100,000 cycles, 105°C (excluding -G type)
NO:
13 A, 120 VAC, resistive, 100,000 cycles, 85°C (AgSnO
2
& -E types, only)
1/2 hp, 125 VAC, 100,000 cycles, 40°C (excluding -G type)
1/3 hp, 125 VAC, 30,000 cycles, 70°C (AgSnO
2
type only, excluding -E, -G types)
400W-T (3.3A), 120 VAC, tungsten, 100,000 cycles (AgSnO
2
type only, excluding -E, -G types)
TV-5, 120 VAC, 40°C (-ASI type only, excluding -E, -G types)
12 A, 250 VAC, general use, 100,000 cycles, 1s=on, 1s=off, 105°C (-E type only)
TV-8,120 VAC, 25,000 cycles, 40°C (-E type only)
10 A, 35 VDC, resistive, 100,000 cycles, 1s=on, 1s=off, 40°C (-G type only)
NC:
12 A, 250 VAC, general use, 30,000 cycles, 1s=on, 9s=off, 40°C (-E type only)
10 A, 35 VDC, resistive, 50,000 cycles, 5s=on, 5s=off, 40°C (-G type only)
1/8 hp, 120 VAC, 50,00 cycles, 40°C (AgSnO
2
type only, excluding -E, -G types)
EN 61810-1, EN 60255, IEC (VDE TUV Reg No. R9151267, VDE Reg No. 6850UG)
Model
G5LE
Coil rating
Approx. 400 mW
3, 5, 6, 9, 12, 24, 48 VDC
Approx. 360 mW
5, 6, 12, 24, 48 VDC
Contact rating
10A, 250VAC (resistive load, 50,000 cycles at 85°C)
5A, 30VDC
2.5 A, 250 VAC (cosφ = 0.4)
PCB Relay
G5LE
175