欢迎访问ic37.com |
会员登录 免费注册
发布采购

RS7302-33DLFSP 参数 Datasheet PDF下载

RS7302-33DLFSP图片预览
型号: RS7302-33DLFSP
PDF下载: 下载PDF文件 查看货源
内容描述: 600毫安可调及固定电压LDO线性稳压器,带有使能,快速放电和Soft.Start [600mA Adjustable & Fixed Voltage LDO Linear Regulator with Enable, Fast Discharge & Soft.Start]
分类和应用: 稳压器
文件页数/大小: 11 页 / 696 K
品牌: ORISTER [ ORISTER CORPORATION ]
 浏览型号RS7302-33DLFSP的Datasheet PDF文件第1页浏览型号RS7302-33DLFSP的Datasheet PDF文件第2页浏览型号RS7302-33DLFSP的Datasheet PDF文件第4页浏览型号RS7302-33DLFSP的Datasheet PDF文件第5页浏览型号RS7302-33DLFSP的Datasheet PDF文件第6页浏览型号RS7302-33DLFSP的Datasheet PDF文件第7页浏览型号RS7302-33DLFSP的Datasheet PDF文件第8页浏览型号RS7302-33DLFSP的Datasheet PDF文件第9页  
Page No. : 3/11
CE & Discharge Function Selection Table 
EEE 
CODE 
NHF 
NLF 
NHN 
NLN 
UHF 
ULF 
EN Type 
Type 1 
None 
None 
None 
None 
Pull High 
Pull High 
Type 2 
High Active 
Low Active 
High Active 
Low Active 
High Active 
Low Active 
Discharge
Fast 
Fast 
Normal 
Normal 
Fast 
Fast 
EEE 
CODE 
UHN 
ULN 
DHF 
DLF 
DHN 
DLN 
EN Type 
Type 1 
Pull High 
Pull High 
Pull Low 
Pull Low 
Pull Low 
Pull Low 
Type 2 
High Active 
Low Active 
High Active 
Low Active 
High Active 
Low Active 
Discharge
Normal 
Normal 
Fast 
Fast 
Normal 
Normal 
Block Diagram 
 
 
 
Absolute Maximum Ratings 
Parameter 
Input Voltage V
IN
 to GND 
Output Current Limit, I
(LIMIT)
 
Junction Temperature 
Thermal Resistance 
SOT‐25 
SC‐70‐5 
SOP‐8 
SOT‐25 
SC‐70‐5 
SOP‐8 
Symbol 
V
IN
 
I
LIMIT
 
T
J
 
θ
JA
 
Ratings 
9.0 
1.0 
+155 
155 
333 
60 
350 
250 
1670 
‐40 ~ +85 
‐55~+150 
+260 
Units
o
o
C/W
Power Dissipation 
P
D
 
T
OPR
 
T
STG
 
‐ 
mW 
o
o
Operating Ambient Temperature 
Storage Temperature 
Lead Temperature (soldering, 10sec) 
o
NOTES: 
1
The power dissipation values are based on the condition that junction temperature T
J
 and ambient temperature T
A
 difference is 
100°C. 
2
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress 
ratings only, and function operation of the device at these or any other conditions beyond those indicated under “recommended 
operating conditions” is not implied. Exposure to absolute‐maximum –rated conditions for extended periods may affect device 
reliability. 
 
 
DS‐RS7302‐02 
   
September, 2009 
www.Orister.com