欢迎访问ic37.com |
会员登录 免费注册
发布采购

DOH06-12T-P 参数 Datasheet PDF下载

DOH06-12T-P图片预览
型号: DOH06-12T-P
PDF下载: 下载PDF文件 查看货源
内容描述: 非隔离式负载的DC / DC转换器点 [Non-isolated Point of load DC/DC converters]
分类和应用: 转换器
文件页数/大小: 3 页 / 217 K
品牌: P-DUKE [ POWER MATE TECHNOLOGY CO., LTD ]
 浏览型号DOH06-12T-P的Datasheet PDF文件第1页浏览型号DOH06-12T-P的Datasheet PDF文件第3页  
Model Name
DOS06-12T
DOS06-12T-P
DOH06-12T
DOH06-12T-P
DOH06-12TA
DOH06-12TA-P
ON/OFF
Logic
Negative
Positive
Negative
Positive
Negative
Positive
Package
SMD
Vertical Mounting
SIP
Horizontal Mounting
SIP
Input Voltage
Vo(set)≦3.63V
Vin = 8.3-14Vdc
Output Voltage
Output Current
Min. Load
Max. Load
Efficiency (%)
12Vin, 3.3Vdc@6A
0.75 ~ 5.0Vdc
Vo(set)>3.63V
Vin = 8.3-13.2Vdc
0A
6A
89%
Note
1. BELLCORE TR-NWT-000332. Case 1: 50% Stress, Temperature at 40ºC.
MIL-HDBK-217F Notice2 @Ta=25 ºC, Full load(Ground, Benign, controlled environment).
2. External with C
out
= 1μF ceramic//10μF tantalum capacitors.
3. External with C
out
= 2×150μF polymer capacitors.
4. Output voltage programmable from 0.7525V to 5V by connecting a single resistor (shown as Rtrim in Table 1) between the TRIM and GND pins of the
module.To calculate the value of the resistor
Rtrim
for a particular output voltage
Vo,
use the following equation:
Rtrim
=
5.
[
10500
Vo
– 0.7525
- 1000
Ω
]
It’s necessary to equip the external input capacitors at the input of the module. The capacitors should connect as close as possible to the input
terminals that ensuring module stability. The external C
in
is 2×47μF ceramic capacitors at least.
6. Device code with suffix “-P” – Positive logic(On/Off is open collector/drain logic input; Signal referenced to GND )
Device code with no suffix – Negative logic (On/Off pin is open collector/drain logic input with external pull –up resistor; signal referenced to GND)
7. Case 1 :On/Off input is set to logic low (module on) and then input power is applied (delay from instant at which Vin=Vin(min) until Vo=10% of Vo(set))
8. Case 2 :Input power is applied for at least one second and then the On/Off input is set to logic low (delay form instant at which Von/off=0.3V until
Vo=10% of Vo(set))
CAUTION:
This power module is not internally fused. An input line fuse must always be used.
DOS06-12T, Vo=3.3V, Derating Curve
7
OUTPUT CURRENT,Io(A)
6
5
4
3
2
1
0
20
30
40
50
60
70
80
90
Fig. 1
AMBIENT TEMPERATURE,TA(℃)
Table 1
Vo(set) (V)
0.7525
1.2
1.5
1.8
2.5
3.3
5
Rtrim (KΩ)
Open
22.46
13.05
9.024
5.009
3.122
1.472
Page 2 of 3
Issued Date:2007/10/12