Multilayer Ceramic Capacitors(High Capacitance)  
Item  
Specification  
Test Method  
Resistance  
Appearance : No mechanical damage  
Soldering bath method  
to Soldering Capacitance change :  
Heat  
Preconditioning : Heat treatment(1)  
Temp. Char. B, X7R, X5R : within 7.5 %  
Solder temperature : 270 5 °C  
Dipping period : 3.0 0.5 s  
Preheat condition :  
F, Y5V : within 20 %  
tan : Initial standard value  
δ
IR : Initial standard value  
Withstand voltage : No dielectric breakdown or damage  
Order Temp. (°C) Size 0805 max. Size 1206  
1
2
80 to 100 120 to 180s 300 to 360s  
150 to 200 120 to 180s 300 to 360s  
Recovery (Standard condition) : 48 4 h  
Solderability More than 95 % of the soldered area of both terminal  
electrodes shall be covered with fresh solder.  
Soldering bath method  
Solder temperature : 230 5 °C  
Dipping period : 4 1 s  
Solder : H63A (JIS–Z–3282)  
Temperature Appearance : No mechanical damage  
Preconditioning : Heat treatment(1)  
Step 1: Minimum operating temp. 30 3 min  
Step 2: Room temp. 3 min max.  
Cycle  
Capacitance change :  
Temp. Char. B, X7R, X5R : within 7.5 %  
F, Y5V : within 20 %  
Step 3: Maximum operating temp. 30 3 min  
Step 4: Room temp. 3 min max.  
tan : Initial standard value  
δ
Number of cycles : 5 cycles  
IR : Initial standard value  
Recovery(Standard condition) : 48 4 h  
Withstand voltage : No dielectric breakdown and/or damage  
Damp Heat  
Appearance : No mechanical damage  
Preconditioning : Heat treatment(1)  
Temperature : 40 2 °C  
(steady state) Capacitance change :  
Temp. Char. B, X7R, X5R : within 20 %  
Relative humidity : 90 to 95 %  
Test period : 500+24/0 h  
F, Y5V : within 30 %  
tan : Temp. Char. B, X7R, X5R : 0.25 max.  
Recovery(Standard condition) : 48 4 h  
δ
F, Y5V : 0.3 max.  
IR : 50/C (M ) min.  
ȑ
Note : 10/C (M ) min. for rated vol. DC 10 V max.  
C:Nominal cap. in µF  
ȑ
Please see the technical specifications for details.  
Damp Heat  
Load  
Appearance : No mechanical damage  
Capacitance change :  
Preconditioning : Voltage treatment(2)  
Temperature : 40 2 °C  
Temp. Char. B, X7R, X5R : within 20 %  
F, Y5V : within 30 %  
Relative humidity : 90 to 95 %  
Applied voltage : Rated voltage  
Charge/discharge current : 50 mA max.  
Test period : 500+24/0 h  
tan : Temp. Char. B, X7R, X5R : 0.25 max.  
δ
F, Y5V : 0.3 max.  
IR : 25/C (M ) min.  
Recovery(Standard condition) : 48 4 h  
ȑ
Note : 5/C (M ) min. for rated vol. DC 10 V max.  
ȑ
C:Nominal cap. in µF  
Please see the technical specifications for details.  
High  
Appearance : no mechanical damage  
Preconditioning : Voltage treatment(2)  
Temperature Capacitance change :  
Temperature : Maximum operation temp. 3 °C  
Load  
Temp. Char. B, X7R, X5R : within 20 %  
Applied voltage : (1)Rated voltage 200 %  
҂
F, Y5V : within 30 %  
(2)Rated voltage 150 %  
҂
tan : Temp. Char. B, X7R, X5R : 0.25 max.  
(3)Rated voltage 100 %  
δ
҂
F, Y5V : 0.3 max.  
Please see the technical specifications  
for details.  
IR : 50/C (M ) min.  
ȑ
Note : 10/C (M ) min. for rated vol. DC 10 V max.  
C:Nominal cap. in µF  
Charge/discharge current : 50 mA max.  
Test period : 1000+48/0 h  
ȑ
Please see the technical specifications for details.  
Recovery (Standard condition) : 48 4 h  
(1) Heat treatment : 1 h of heat treatment at 150+0/–10 °C followed by 48 4 h recovery under standard conditions.  
(2)Voltage treatment : 1 h of voltage treatment under the specified temperature and voltage for testing followed by 48 4 h of recovery under  