Multilayer Ceramic Capacitors(4 Array Type)
■
Temperature Characteristics
●
Class 1
Temperature
Temperature
Characteristic Code Characteristics
C
●
Class 2
Temperature
Characteristic Code
B
F
CH
Temp. Coeff.
(ppm/°C)
0 ± 60
Rate of Capacitance change at each Temp. (%)
–25 °C
85 °C
max.
min.
max.
min.
0.49
–0.27
0.39
–0.39
Temperature coefficient: calculated between 20 °C to 85 °C
Temperature
Characteristics
B
X7R
X5R
F
Y5V
Capacitance Change
±10 %
±15 %
±15 %
+30, –80 %
+22, –82 %
Measurement
Temperature Range
–25 to 85 °C
–55 to 125 °C
–55 to 85 °C
–25 to 85 °C
–30 to 85 °C
Reference Temperature
20 °C
25 °C
25 °C
20 °C
25 °C
For applicable “temperature characteristics”, see the lists of standard products on page 31 to 32.
■
Rated Voltage
Code
Rated Voltage
1H
DC 50 V
1E
DC 25 V
1C
DC 16 V
1A
DC 10 V
0J
DC 6.3 V
■
Nominal Capacitance
Ex.
Nominal
Capacitance
100
10 pF
101
100 pF
104
100,000 pF
(0.1 µF)
105
1,000,000 pF
(1.0 µF)
■
Capacitance tolerance
Class
1
CH
Temperature Characteristics
C=10 pF
Capacitance range
C>10 pF
B, X7R, X5R
2
F, Y5V
Z
+80, –20 %
K
M
±10 %
±20 %
Tolerance Code
F
Capacitance Tolerance
±1 pF
■
Specifications and Testing Methods
Item
Operating
Temperature
Range
Dielectric
Withstanding
Voltage
Specifications
Class 1
Temp. Char.
CH: –55 to 125 °C
Class 2
Temp. Char.
B, X7R: –55 to 125 °C
X5R: –55 to 85 °C
F, Y5V: –30 to 85 °C
No dielectric breakdown and/or damage
Test Method
———
Test voltage:
Class 1: Rated voltage
300 %
Class 2: Rated voltage
250 %
Duration: 1 to 5 s
Charge/discharge current: 50 mA max.
Measuring voltage: Rated voltage
Duration: 60±5 s
Charge/discharge current: 50 mA max.
Measuring temperature: 20±2 °C
Class 1
Measuring frequency
Measuring voltage
1 MHz ± 10 %
0.5 to 5 Vrms
10000 M or 500/C (M ) Whichever is less
Note: 100/C (M ) min. for DC 10 V max.
C: Nominal Cap. in µF
Capacitance
Within the specified tolerance
tan
δ:
Q Factor or
Q:
Temp. Char.
Dissipation Factor
C < 30 pF: Q
>400+20
C
B, X7R: 0.025 max.
(tan
δ)
30 pF<C
<1000
pF:
X5R: 0.075 max.
Q
>1000
F, Y5V: 0.125 max.
Please see the technical
C: Nominal Cap. in pF
specifications for details.
Insulation
Resistance (IR)
Class 2
Preconditioning: The capacitors shall be
kept in temperature of 150 +0/–10 ± for 1
hour and subject to standard conditions
½
for 48±4 hours before initial measurement.
Measuring frequency
Measuring voltage
1 kHz ± 10 %
1.0±0.2 Vrms
½
Standard condition: Temperature 15 to 35 °C, Relative humidity 45 to 75 %.
For further information, see the technical specifications.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
00 Sep. 2008
– EC29 –