10 Base-T Interface Module
PCA Part Number(s)
Parameter
Cut-off Frequency
Insertion Loss
(See Note 1) 1-10 MHz
Attenuation
(See Note 1)
20 MHz
25 MHz
30 MHz
40 MHz
Return Loss
Common Mode Rejection
Isolation
Hipot
Crosstalk
Impedance Ratio
5-10 MHz
1-100 MHz
1-500 MHz
-----
-----
1-10 MHz
1500 (for 1 Minute)
500 (for 1 Minute) Xmit to Rcv
35 (Between Channels), Xmit to Rcv
200
100
EPA2352
Specification
XMIT
1.5
7.0
17.0
28.0
33.0
15.0
---
38.0
Electrical Specifications @ 25 °C
Frequency
16.5 ± 1.0
1.0
5.0
11.0
16.0
26.0
15.0
30.0
---
RCV
Unit
MHz
dB Max.
dB Min.
dB Min.
dB Min.
dB Min.
dB Min.
dB Min.
dB Min.
Vrms
Vrms
dB Min.
Ω
± 10%
Notes :
1. Referenced to Filter Output @ 5 MHz. Insertion Loss due to filter effects only, resistive elements not
included.
Xmit : 7 Pole Balanced Low-Pass, 100Ω ; Rcv : 5 Pole Balanced Low-Pass, 100Ω
Schematic
1
2
2.4KΩ
62Ω
261Ω
X'MIT
8
2.2MΩ
LPF
7
2.2MΩ
3
62Ω
4
261Ω
6
5
RCV
16
51Ω
15
51Ω
14
9
Package
PCA
EPA2352
Date Code
.410
Max.
Leads : .018 x .012
LPF
12
10
11
White Dot Marks Pin 1
1.000 Max.
.450
Max.
.020
.100 Typ.
.120
Min.
.300
DSA2352
Rev. A
9/18/95
QAF-CSO7 8/10/94
Unless Otherwise Noted Dimensions in Inches
Tolerances:
Fractional = ± 1/32
.XX = ± .030
.XXX = ± .010
ELECTRONICS
INC.
16799 SCHOENBORN ST.
NORTH HILLS, CA 91343
TEL: (818) 892-0761
FAX: (818) 894-5791