欢迎访问ic37.com |
会员登录 免费注册
发布采购

EPF8057S 参数 Datasheet PDF下载

EPF8057S图片预览
型号: EPF8057S
PDF下载: 下载PDF文件 查看货源
内容描述: 10 / 100BX模块为多端口应用 [10/100BX Module for Multi-port Applications]
分类和应用: 变压器脉冲通信变压器数据通信变压器100BX100磅局域网(LAN)标准
文件页数/大小: 2 页 / 52 K
品牌: PCA [ PCA ELECTRONICS INC. ]
 浏览型号EPF8057S的Datasheet PDF文件第1页  
10/100BX Module for
Multi-port Application
ELECTRONICS INC.
The circuit below is a guideline for interconnecting PCA’s EPF8057S with National DP83840A and DP83223 twister chip set
for 10/100 Mb/s applications. Further details can be obtained from the chip manufacturer application notes. Please
consult PCA for applications help regarding the SSI78Q2120 or ICS1890 series parts or consult with the respective
application notes.
Typical insertion loss of the isolation transformer is 0.8dB. This parameter covers the entire spectrum of the encoded
signals in 10/100 protocols. Under terminated conditions, to transmit a 2V pk-pk signal across the cable, you must adjust
the TXREF resistor of the twister chip to get at least 2.12V pk-pk across pins 1-2. Note that insertion loss is only 0.5 dB
max at 100 KHz. This ensures proper operation with transceivers such as ML6673 with any length of cable. Follow the
latest circuit recommendations for ML6673 from Micro Linear Applications group. Circuit designers do not need to use the
pins 4 and 5 for applications with ICS 1890, TSC 78Q2120 or ML6673. These inputs allow more effective connection with
the low impedance drivers of the DP83840A while providing balanced drive capability for both DP83840A and the
DP83223(A). Parts similar to EPF8057S are available from several LAN magnetics vendors.
It is recommended that system designers do not ground the receiver side center tap, via a capacitor. This may worsen
EMI, specifically if the secondary “common mode termination” is pulled to chassis ground as shown.
The phantom resistors shown around the connector have been known to suppress unwanted radiation that unused wires
pick up from the immediate environment. Their placement and use are to be considered carefully before a design is
finalized.
The “common mode termination” load of 75
shown from the center taps of the secondary may be taken to chassis ground
via a cap of suitable value. This depends upon user’s design, EMI margin etc.
It is recommended that there be a neat separation of ground planes in the layout. It is generally accepted practice to limit
the plane off at least 0.05 inches away from the chip side pins of EPF8057S. There need not be any ground plane beyond
this point.
For best results, PCB designer should design the outgoing traces preferably to be 50
Ω,
balanced and well coupled to
achieve minimum radiation from these traces.
Typical Application Circuit for UTP (only one port shown)
0.10µF {Note 1}
+
7
1000pF
12.1Ω
0.1µF
{Note 1}
34
Rcv
33
75Ω
50Ω
8
7
1
5
4
Xmit
2
75Ω
RXD
-
8
32
TXU
+
12.1Ω
-
1000pF
+
+
-
4
5
1
2
TXO
50Ω
40
39
38
2000V
RJ45*
1
6
3
Chassis
Ground
EPF8057S
Isolation Cap
TD
-
PMRD
RXI
DP83840A
+
DP83223
SD
PMID
Other pull down/up resistors not shown, for clarification please refer to National’s application notes.
Notes : 1. See text above for clarification.
2. Hub side connections show only one port.
SD
-
+
RD
-
PCA ELECTRONICS, INC.
16799 SCHOENBORN ST.
NORTH HILLS, CA 91343
CSF8057Sb Rev. 2 5/22/97
TEL: (818) 892-0761
FAX: (818) 894-5791
http://www.pcainc.com