Product Specification
R2005240
Si Reverse, 5 – 200MHz, 24.6dB typ. Gain @ 200MHz, 235A max. @ 24VDC
CHARACTERISTICS
Table 2: Distortion data 5 – 200 MHz; V
B
= 24V; T
mb
= 30°C; Z
S
= Z
L
= 75
Ω
SYMBOL
CTB
XMOD
CSO
d
2
V
0
Notes:
1)
2)
3)
PARAMETER
composite triple beat
cross modulation
composite second order
second order distortion
output voltage
CONDITION
22 ch. flat; Vo = 50 dBmV
22 ch. flat; Vo = 50 dBmV
D
im
= -60 dB
1)
MIN.
-
-
-
64.0
TYP.
MAX.
- 69
- 60
- 67
- 67
UNIT
dBc
dB
dBc
dBc
dBmV
22 ch. flat; Vo = 50 dBmV
1)
1)
2)
3)
22 channels, NTSC frequency raster: T7 – T13 (7.0 to 43.0 MHz), 2 - 6 (55.25 – 83.25 MHz), A – 7 (121.25 –
175.25MHz), +50 dBmV flat output level.
f
1
= 83.25 MHz; V
1
= 50 dBmV; f
2
= 109.25 MHz; V
2
= 50 dBmV; f
TEST
= f
1
+ f
2
= 192.5 MHz.
f
1
= 187.25 MHz; V
1
= 50 dBmV; f
2
= 194.25 MHz; V
2
= V
1
– 6dB; f
3
= 196.25 MHz; V
3
= V
1
– 6dB;
f
TEST
= f1 + f2 - f3 = 185.25 MHz, according to DIN45004B.
Composite Second Order (CSO)
The CSO parameter (both sum and difference products) is defined by the NCTA.
Composite Triple Beat (CTB)
The CTB parameter is defined by the NCTA.
Cross Modulation (XMOD)
Cross modulation (XMOD) is measured at baseband (selective voltmeter method), referenced to 100% modulation of the
carrier being tested.
Page 2 of 4
2004 Jun 01
Document Revision Level D