POE60U Characteristics
INPUT:
AC Input Voltage Range
90 to 264VAC
WWW.PHIHONG.COM
EMC
FCC Part 15 Class B
EN55022 Class B
AC Input Voltage Rating
100 to 240VAC,47-63Hz
Isolation Test
Primary to Secondary: 3000VAC for 1 minute 10mA
Primary to F.G.: 1500VAC for 1 minute
Output to F.G.: 1500VAC
AC Input Current
1A(RMS) max. for 90VAC
0.7A(RMS) max. for 240VAC
Immunity
Leakage Current
0.25mA max. @ 254VAC 60Hz
ESD:
RS:
EFT:
Surge:
CS:
Voltage Dips
Harmonic:
EN61000-4-2. Level 3
EN61000-4-3. Level 2
EN61000-4-4. Level 2
EN61000-4-5. Level 3
EN61000-4-6. Level 2
EN61000-4-11
EN61000-3-2
AC Inrush Current
15A(RMS) max. for 115VAC
20A(RMS) max. for 230VAC
OUTPUT:
Total Output Power
60W
Insulation Resistance
Primary to secondary: >10M OHM 500VDC
Primary to FC: >10M OHM 500VDC
DC Offset
No Data degradation with DC imbalance 18mA per min.
FEATURES:
Detection
Same as IEEE802.3af except 12.5kohm detection
resistor value required at Powered device.
Over Voltage/Current, Short Circuit Protection
Outputs equipped with short circuit protection and overload
protection as per 802.3af specification except max average
current is 0.55A, Peak 0.6A per pair
The output can be shorted permanently without damage
Efficiency
65% (typical) at Max. load, and 120VAC 60Hz
Hold-up Time
16mS min. 120VAC and max. load
Transient O/P Voltage Protection
60V max.
ENVIRONMENTAL:
Temperature
Operation
Non-operation
0 to +40°C
-25 to +65°C
Indicators
Led #1 indicator for input power “on” GREEN
Led #2 Indicator for fault-RED
Led #3 Indicator that Detected and Connected to valid
IEEE802.3af load-GREEN
Humidity
Operation
5 to 90%
Input Connector
IEC320 inlet 3 pin
Dimension Diagram Unit: mm (inch)