PSA21R Characteristics
INPUT:
Rated Input Voltage
100 to 240 VAC
Operating Input Voltage
90 to 264 VAC
AC Input Frequency
47 to 63Hz
AC Input Current
1.0Arms (120VAC)
0.5Arms (240VAC)
AC Inrush Current (Cold)
30A max. (120VAC)
60A max. (240VAC)
Efficiency
70% typical
OUTPUT:
Hold-up Time
16ms Full load, 115VAC
Overvoltage Protection
>120%
Short Circuit Protection
Auto Restart
ENVIRONMENTAL:
Operation Temperature
0 to 40°C
Storage Temperature
-25 to +85°C
Humidity
10 to 90% RH (Non-condensing)
Emissions
FCC Class B
EN 55022 B
Immunity
EN 50082-1: 1997
61000-4-2, Level 3
61000-4-3, Level 2
61000-4-4, Level 2
61000-4-5, Level 3
61000-4-6, Level 3
61000-4-11
GENERAL:
Leakage Current
<0.25mA (254VAC)
Dielectric Withstand (Hipot)
Input to Output
3000VAC, 1 min., 10mA
Switching Frequency
65KHz (12 to 24V)
100KHz (3.3 to 9V)
MTBF (Full Load, 25°C)
150K Hrs.
MIL-HDBK-217F
Power On Indicator
Green LED
AC Input Plugs
(Order Separately)
USA: RPA
Europe: RPE
UK:RPK
Australia:RPS
DC Output Connector
2.1mm x 5.5mm x 10mm Coaxial
Plug;Center Positive Standard
WWW.PHIHONG.COM
PSA21R/0312
A D A P T E R