欢迎访问ic37.com |
会员登录 免费注册
发布采购

PL660-09 参数 Datasheet PDF下载

PL660-09图片预览
型号: PL660-09
PDF下载: 下载PDF文件 查看货源
内容描述: 模拟倍频器 [Analog Frequency Multiplier]
分类和应用: 倍频器
文件页数/大小: 15 页 / 484 K
品牌: PLL [ PHASELINK CORPORATION ]
 浏览型号PL660-09的Datasheet PDF文件第3页浏览型号PL660-09的Datasheet PDF文件第4页浏览型号PL660-09的Datasheet PDF文件第5页浏览型号PL660-09的Datasheet PDF文件第6页浏览型号PL660-09的Datasheet PDF文件第8页浏览型号PL660-09的Datasheet PDF文件第9页浏览型号PL660-09的Datasheet PDF文件第10页浏览型号PL660-09的Datasheet PDF文件第11页  
Analog Frequency Multiplier
PL660 and PL663 XO Families
120 MHz AFM Tuning:
Using the “AFM Tuning Assistant” find the PL660-0x in the L2X worksheet. Enter the
Cinternal value found next to it into cell B21. In cell B24 enter the closest standard inductor value (see CoilCraft
0603CS series for example) to achieve the closest peak frequency to 60 MHz. Repeat the same procedure for
L4X at 120 MHz.
Results: L2X = 180 nH, L4X = 82 nH.
320 MHz AFM tuning:
Repeat the previous procedure for L2X at 120 MHz and L4X at 320 MHz.
Results: L2X = 24 nH, L4X = 10 nH.
Proceed and assemble the test units.
Measuring 120 MHz L2X:
Connect the RF generator and scope probe as shown in Figure 6. While power is
applied to the PCB, set the generator output to +12 dBm and the frequency to 30 MHz. Since this is the 2x port,
the scope will show 60 MHz with ~ 3V pk-pk amplitude. Vary the generator above and below 30 MHz until the
amplitude on the scope is maximum and record the generator frequency. For example peak recorded at 29.8x2 or
59.6 MHz.
Measuring 320 MHz L2X:
Connect the RF generator and scope probe as shown in Figure 6. While power is
applied to the PCB, set the generator output to +12 dBm and the frequency to 80 MHz. Since this is the 2x port the
scope will show 160 MHz with ~ 3V pk-pk amplitude. Vary the generator above and below 80 MHz until the
amplitude on the scope is maximum and record the generator frequency. For example peak recorded at 78.0 x 2 =
156 MHz
In the AFM Tuning Assistant, add the scope’s probe capacitance to the Cstray cell. For our example 0.5 pF + 1.0
pF = 1.5 pF. With L2X at 24 nH adjust LWB1 (cell B23) until the peak frequency reads 156 MHz. Next replace the
L2X value with 180 nH and see if it peaks at 59.6 MHz. If it does not, adjust the Cstray until 59.4 MHz is achieved.
Again enter 24 nH for L2X and fine tune LWB1 for 156 MHz.
Results: LWB1 = 1.6 nH, Cstray = 2.9 pF-0.5 pF = 2.4 pF (subtract scope probe stray)
Repeat the same steps for the L4X: Set the generator to 80 MHz. The 82 nH peaks at 118 MHz and the 10 nH
peaks at 304 MHz.
Results: LWB1 = 1.8 nH, Cstray = 2.5 pF-0.5 pF = 2.0 pF (subtract scope probe stray)
Internal Capacitor Selection by Device
Device Number
PL660-0X
PL663-0X
PL663-1X
PL663-2X
Cinternal (pF)
2X
34.125
46.500
14.625
14.625
4X
16.500
47745 Fremont Blvd., Fremont, California 94538 TEL (510) 492-0990, FAX (510) 492-0991
www.phaselink.com
Rev. 3/20/07 Page 7