欢迎访问ic37.com |
会员登录 免费注册
发布采购

20IMX7-03-8 参数 Datasheet PDF下载

20IMX7-03-8图片预览
型号: 20IMX7-03-8
PDF下载: 下载PDF文件 查看货源
内容描述: [IMX7/IMS7 DC-DC Series Data Sheet 7-Watt DC-DC Converters]
分类和应用:
文件页数/大小: 15 页 / 380 K
品牌: POWER-ONE [ POWER-ONE ]
 浏览型号20IMX7-03-8的Datasheet PDF文件第7页浏览型号20IMX7-03-8的Datasheet PDF文件第8页浏览型号20IMX7-03-8的Datasheet PDF文件第9页浏览型号20IMX7-03-8的Datasheet PDF文件第10页浏览型号20IMX7-03-8的Datasheet PDF文件第12页浏览型号20IMX7-03-8的Datasheet PDF文件第13页浏览型号20IMX7-03-8的Datasheet PDF文件第14页浏览型号20IMX7-03-8的Datasheet PDF文件第15页  
IMX7/IMS7 DC-DC Series Data Sheet  
7-Watt DC-DC Converters  
®
Electromagnetic Compatibility (EMC)  
A suppressor diode together with an input filter form an  
effective protection against high input transient voltages, which  
typically occur in many installations, but especially in battery-  
driven mobile applications.  
Electromagnetic Immunity  
Table 8: Immunity type tests  
Phenomenon  
Standard  
Class  
level  
Coupling  
mode 1  
Value  
applied  
Waveform  
Source  
imped.  
Test  
procedure  
In  
Per-  
oper. form.2  
Electrostatic  
discharge  
to case5  
IEC/EN  
61000-4-2  
2
3
contact discharge  
air discharge  
antenna  
4000 Vp  
8000 Vp  
1/50 ns  
330 Ω  
10 positive and  
10 negative  
discharges  
yes  
B
Electromagnetic IEC/EN  
field  
36  
23  
10 V/m  
3 V/m3  
AM 80%  
1 kHz  
n.a.  
n.a.  
80 – 1000 MHz  
yes  
yes  
A
A
ENV 50204  
3
23  
antenna  
10 V/m  
3 V/m3  
PM, 50% duty  
cycle, 200 Hz  
repetition frequ.  
900 MHz  
Electrical fast  
transients/burst  
IEC/EN  
61000-4-4  
4
33  
direct +i/–i  
4000 Vp bursts of 5/50 ns  
2000 Vp 5 kHz repet. rate,  
50 Ω  
60 s positive,  
60 s negative  
transients per  
coupling mode  
yes  
B
3
transients with  
15 ms burst  
duration, and  
300 ms period  
Surges  
IEC/EN  
61000-4-5  
3 4  
+i/–i  
+i/–i  
2000 Vp  
1000 Vp  
1.2/50 μs  
2 Ω  
5 pos. and 5 neg.  
surges  
yes  
yes  
B
A
3
23 4  
RF conducted  
immunity  
IEC/EN  
61000-4-6  
3
23  
10 VAC  
3 VAC  
AM modul. 80%  
1 kHz  
50 Ω  
0.15 to 80 MHz  
150 Ω  
1
i = input, o = output  
2
3
4
5
6
Performance criterion: A = normal operation, no deviation from specifications, B = temporary deviation from specs possible  
Valid for 24IMS7 and 48IMS7  
External components required  
R or Trim pin open, i pin connected with Vi–  
Corresponds to the railway standard EN 50121-3-2:2000, table 9.1  
Electromagnetic Emissions  
Date: 5.9.07  
40IMX7-24-24-8 Peak  
Time: 08:00  
PMM 8000 PLUS  
Name: 40_7_24  
Date: 5.9.07  
Time: 08:18  
PMM 8000 PLUS  
Name: 20_7_15  
dbμV  
80  
20IMX7-15-15-8 Peak  
dbμV  
80  
EN 55022 A  
EN 55022 A  
60  
40  
60  
40  
20  
0
20  
0
0.2  
0.5  
1
2
5
10  
20 MHz  
0.2  
0.5  
1
2
5
10  
20 MHz  
Fig. 16b  
Fig. 16a  
40IMX7-24-24-8: Typical conducted emissions (peak) at the  
input at Vi nom and Io nom according to EN 55011/22. Output  
leads 0.1 m, twisted. External input capacitor (1 μF ceramic +  
47 μF electrolytic cap)  
20IMX7-15-15-8: Typical conducted emissions (peak) at the  
input at Vi nom and Io nom according to EN 55011/22. Output  
leads 0.1 m, twisted. External input capacitor (1 μF ceramic +  
100 μF electrolytic cap)  
BCD20007-G Rev AD, 4-Nov-09  
Page 11 of 15  
www.power-one.com