Board Mountable
Input
Input voltage
continuous range, 12 V
continuous range, 24 V
continuous range, 48 V
reverse input voltage, current limitation
IMR Series
9...18 V DC
18...36 V DC
36...72 V DC
Protection
Output
Efficiency
Minimum load
Line regulation
Load regulation
recommended
U
i min
...U
i max
,
I
o nom
U
i nom
, 0...100%
I
o nom
, single output models
dual output models (traching)
triple output models (traching)
U
i nom
, (20...100%)
I
o nom
up to 82%
20%
I
o nom
±1%
2%
5%
6%
2%
U
o nom
Ripple and noise
Protection
Overload protection
No-load protection
U
i nom
, full load
125%
P
i nom
Safety
I/O electric strength test
Electromagnetic interference
per EN 60950
conducted per EN 55022 with external filter
500 V DC
class B
Environmental
Operating temperature
Storage temperature
Relative humidity
MTBF
U
i nom
,
I
o nom
non operational
non condensing
per MIL-HDBK-217F, N2
–10...50°C
–40...100°C
95%
>3'000'000 h
Options
Extended temperature range
–25...71°C, ambient, operating, IMR 3, IMR 6
-7
www.power-one.com
Edition 5/07.2001
2