S Series
Environmental
Operating ambient temperature
Operating case temperature
T
C
Storage temperature
Damp heat
Vibration, sinusoidal
Shock
Bump
Random vibration
MTBF
100 Watt DC-DC Converters
U
i nom
,
I
o nom
, convection cooled
U
i nom
,
I
o nom
non operational
IEC/EN 60068-2-3, 93 %, 40
°C
IEC/EN 60068-2-6, 10...60/60...2000 Hz
IEC/EN 60068-2-27, 6 ms
IEC/EN 60068-2-29, 6 ms
IEC/EN 60068-2-64, 20...500 Hz
MIL-HDBK-217F, G
B
, 40°C
–25...71°C
–25...95°C
–40...100°C
56 days
0.35 mm/5 g
n
100 g
n
40 g
n
4.9 g
n rms
500'000 h
Options
Extended temperature range
–40...71°C, ambient, operating
Electronic inrush current limitation
Output voltage adjustment
40...110%
U
o nom
, excludes feature R and vice versa
Input and/or output undervoltage monitoring, excludes option V
Input and/or output undervoltage monitoring (VME), excludes option D
Current sharing
Cooling plate
-9
E
P
D0…D9
V0, V2, V3
T
B1
Pin allocation
Pin
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
Vo1+
Vo1+
Vo1–
Vo1–
S+
S–
R
i
D
V
T
Vi+
Vi+
Vi–
Vi–
AS...ES 1000
Output 1
Output 1
Sense
Sense
Control of
U
o1
Inhibit
Save data
ACFAIL
Current sharing
Protective earth
Input
Input
AS...ES 2000
Vo2+
Output 2
Vo2+
Vo2–
Output 2
Vo2–
Vo1+
Output 1
Vo1–
R
Control of
U
o1
i
Inhibit
D
Save data
T
Vi+
Vi+
Vi–
Vi–
S10002
Current sharing
Protective earth
Input
Input
30 26 22 18 14 10
6
32 28 24 20 16 12
8
4
www.power-one.com