Cassette Style
Input
Input voltage
Inrush current limitation
6 wide-input ranges (1:5)
FS, CS, DS, ES by thermistor
S Series
refer to selection chart
Output
Efficiency
Output voltage setting accuracy
Output voltage switching noise
Line regulation
Load regulation
Minimum load
Current limitation
Operation in parallel
Hold-up time
U
i nom
,
I
o nom
up to 86%
U
i nom
,
I
o nom
±0.6%
U
o nom
IEC/EN 61204, total
typ. 100 mV
pp
U
i min
…
U
i max
,
I
o nom
typ.
±0.3%
U
o nom
U
i nom
, 10...100%
I
o nom,
symmetrical output load typ. 0.4%
U
o nom
not required
0A
rectangular U/I characteristic
typ. 110%
I
o nom
by current limitation
U
i nom
,
I
o nom
, CS/DS/ES/FS with ext. diode in input line 12...40 ms
U
i nom
,
I
o nom
, AS/BS with ext. diode in input line
typ. 1.8 ms
Control and protection
Input reverse polarity
Input undervoltage lockout
Input overvoltage lockout
Input transient protection
Output
Output overvoltage
Overtemperature
Output voltage adjustment
Inhibit
Status indication
built-in fuse not user accessible
typ. 80%
U
i min
typ. 108%
U
i max
varistor or suppressor diode
no-load, overload and short circuit proof
suppressor diode in each output
switch-off with auto restart
TTL input, output(s) disabled if open circuit
LEDs: OK, inhibit, overload
typ. 130%
U
o nom
T
C
typ. 100°C
0...110%
U
o nom
Safety
Approvals
Class of equipment
Protection degree
Electric strength test voltage
EN 60950, UL 1950, CSA 22.2 No. 950
class I
IP 30
2 kV AC
4 kV AC
1 kV AC
0.1 kV AC
I/case
I/O
O/case
O/O
EMC
Electrostatic discharge
Electromagnetic field
Electr. fast transients/bursts
Surge
Conducted disturbances
Electromagnetic emissions
IEC/EN 61000-4-2, level 4 (8/15 kV)
IEC/EN 61000-4-3, level x (20 V/m)
IEC/EN 61000-4-4, level 4 (2/4 kV)
IEC/EN 61000-4-5, level 3 (2 kV)
IEC/EN 61000-4-6, level 3 (10 V)
CISPR 22/EN 55022, conducted
criterion A
criterion A
criterion A
criterion A
criterion A
class B
www.power-one.com
2