欢迎访问ic37.com |
会员登录 免费注册
发布采购

LS5320-7R 参数 Datasheet PDF下载

LS5320-7R图片预览
型号: LS5320-7R
PDF下载: 下载PDF文件 查看货源
内容描述: 100瓦AC- DC转换器, PFC [100 Watt AC-DC Converters with PFC]
分类和应用: 转换器功率因数校正输出元件
文件页数/大小: 27 页 / 598 K
品牌: POWER-ONE [ POWER-ONE ]
 浏览型号LS5320-7R的Datasheet PDF文件第2页浏览型号LS5320-7R的Datasheet PDF文件第3页浏览型号LS5320-7R的Datasheet PDF文件第4页浏览型号LS5320-7R的Datasheet PDF文件第5页浏览型号LS5320-7R的Datasheet PDF文件第6页浏览型号LS5320-7R的Datasheet PDF文件第7页浏览型号LS5320-7R的Datasheet PDF文件第8页浏览型号LS5320-7R的Datasheet PDF文件第9页  
Cassette Style
100 Watt AC-DC Converters
S Series PFC
100 Watt AC-DC Converters with PFC
Input voltage range from 85...264 V AC
1 or 2 isolated outputs up to 48 V DC
4 kV AC I/O electric strength test voltage
Universal input voltage range
Power factor
>0.95,
harmonics
<IEC/EN
61000-3-2
Input over- and undervoltage lock-out
Efficient input filter and built-in surge and transient
suppression circuitry
Fully isolated outputs
Outputs overload, open- and short-circuit proof
No derating over entire operating temperature range
Safety according to IEC/EN 60950
LGA
S Series
111
4.4"
3U
60
2.4"
12 TE
168
6.6"
Summary
The S 4000/S 5000 series of AC-DC converters represents
a flexible range of power supplies for use in advanced elec-
tronic systems. Features include full power factor correc-
tion, high efficiency, high reliability, low output voltage noise
and excellent dynamic response to load/line changes.
The converter inputs are protected against surges and tran-
sients occurring at the source lines. An input over- and
undervoltage lock-out circuitry disables the outputs if the
input voltage is outside the specified range. Inrush current
limitation is included preventing circuit breakers and fuses
from being damaged at switch-on.
All outputs are overload, open- and short-circuit proof and
are protected against overvoltages by means of a built-in
suppressor diode. The outputs can be inhibited by a logic
signal applied to the connector pin 18 (i). If the inhibit func-
tion is not used pin 18 must be connected to pin 14 to en-
able the outputs.
LED indicators display the status of the converter and allow
visual monitoring of the system at any time.
Full input to output, input to case, output to case and output
to output isolation is provided. The modules are designed
and built according to the international safety standards
IEC/EN 60950 and have been approved by the safety
agencies LGA (Germany) and UL (USA). The UL Mark for
Canada has been officially recognized by regulatory au-
thorities in provinces across Canada.
The case design allows operation at nominal load up to
71°C in a free air ambient temperature. If forced cooling is
provided, the ambient temperature may exceed 71°C but
the case temperature must remain below 95°C under all
conditions.
A temperature sensor generates an inhibit signal which
disables the outputs if the case temperature
T
C
exceeds
the limit. The outputs are automatically re-enabled when
the temperature drops below the limit.
Various options are available to adapt the converters to in-
dividual applications.
The modules may either be plugged into 19" rack systems
according to DIN 41494, or be chassis mounted.
Important:
These products are intended to replace the LS 1000 and
LS 2000 in order to comply with IEC/EN 61000-3-2.
Table of Contents
Page
Page
Electromagnetic Compatibility (EMC) ............................ 15
Immunity to Environmental Conditions ........................... 17
Mechanical Data ............................................................ 18
Safety and Installation Instructions ................................ 19
Description of Options .................................................... 22
Accessories .................................................................... 27
Summary .......................................................................... 1
Type Survey and Key Data .............................................. 2
Type Key .......................................................................... 2
Functional Description ...................................................... 3
Electrical Input Data ......................................................... 4
Electrical Output Data ...................................................... 6
Auxiliary Functions ......................................................... 11
Edition 01/01.2001
1/27