欢迎访问ic37.com |
会员登录 免费注册
发布采购

MAP130-4004 参数 Datasheet PDF下载

MAP130-4004图片预览
型号: MAP130-4004
PDF下载: 下载PDF文件 查看货源
内容描述: 自动115/230输入电压选择 [Automatic 115/230 Input Voltage Selection]
分类和应用:
文件页数/大小: 4 页 / 246 K
品牌: POWER-ONE [ POWER-ONE ]
 浏览型号MAP130-4004的Datasheet PDF文件第1页浏览型号MAP130-4004的Datasheet PDF文件第2页浏览型号MAP130-4004的Datasheet PDF文件第4页  
MAP130 SERIES
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Overvoltage Protection
Provided on single output units and only
the main output of multiple output units.
Overcurrent Protection
Remote Sense
Power Fail Warning
(Note 1)
Overtemperature Warning
(Note 2)
MAP130-1012
17.0
MAP130-1024
32.0
MAP130-4004
6.2
All other models.
5.5
All models have inherent short circuit protection. Units will automatically restart at the removal of the fault.
Total voltage compensation for main output cable losses.
Logic LO (denotes power fail detected).
Logic HI with internal pull-up to output.
10
Power Fail trip point, maximum load, decreasing line.
86
Time before regulation dropout, at full load, due to loss of input power.
5
Warning prior to system shutdown due to excessive internal temperatures.
20
Shifts Power Fail signal to a logic LO state.
22.0
37.0
7.4
6.8
250
0.7
94
VDC
mV
V
kΩ
VAC
mS
mS
NOTES:
1) Power Fail not available on MAP130-1012 and MAP130-1024.
2) MAP130-1012 and MAP130-1024 have overtemperature protection, but do not have the warning feature.
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Agency Approvals
Dielectric Withstand Voltage
Electromagnetic
Interference,
ESD Susceptibility
Radiated Susceptibility
EFT/Burst
Input Transient Protection
Insulation Resistance
Leakage Current
UL1950.
CSA 22.2 No. 234/950.
EN60950 (TÜV).
Input to Output, 1 second.
FCC CFR title 47 Part 15 Sub-Part B - Conducted
EN55022 / CISPR 22 Conducted
EN55022 / CISPR 22 Radiated (Note 1)
Per EN61000-4-2, level 4
Per EN61000-4-3, level 3
Per EN61000-4-4, level 3 (Note 2)
Per EN61000-4-5 class 3
Input to output
Per EN60950 (264 VAC)
Approved
2600
B
B
B
8
10
±2
Line to Line
1
Line to Ground 2
7
700
VDC
Class
kV
V/M
kV
kV
MΩ
µA
NOTES:
1) MAP130-1005 meets Class A, radiated.
2) MAP130-1005, MAP130-4003, and MAP130-4010, meet level 2, ±1kV.
ENVIRONMENTAL SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Altitude
Operating Temperature
Operating
Non-Operating
Derate linearly above 50°C by 2.5% per °C
At 100% load:
At 50% load:
0
-40
0°C to 70°C (after 15 minute warm-up period)
Non-Condensing
Operating, peak acceleration
Random vibration, 10Hz to 2kHz, 3 axis
±0.02
5
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
Vibration
10K
40K
50
70
85
±0.05
95
20
6
Feet
°C
°C
°C
%/°C
%RH
G
PK
G
RMS
OPTIONS
DESCRIPTION
NOTES
DIMENSIONS
Cover
Add ‘C’ suffix to model number or order part number 412-59586 separately.
For convection cooled applications with covers, derate output power as follows:
Derate all multiple output models and MAP130-1005 to 120 watts.
Derate MAP130-1012 and MAP130-1024 to 140 watts.
8.50" x 4.50" x 2.40"
(215.9mm x 114.3mm x 61.0mm)
3