MAP30/40/42 SERIES
Power-One’s MAP30/40/42 series of power supplies combines low cost
and universal input in a board-only power solution to meet
commercial and industrial requirements. Full international safety,
EMI, and ESD compliance ensure world-wide acceptance. All units
bear the CE Mark.
FEATURES
• Universal Input 85-264 VAC
• CE Marked to Low Voltage Directive
• Input Transient & ESD Compliance to EN61000-4-2/-3/-4
• Meets EN55022 Conducted and Radiated Limits
• Greater than 311,000 Hours MTBF
• Remote Sense (MAP30, MAP42)
SINGLE OUTPUT MODEL SELECTION CHART
MODEL
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT
PEAK OUTPUT
CURRENT (NOTE 2)
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%p-p (NOTE 1)
INITIAL SETTING
ACCURACY
Fixed frequency operation simplifies system level operation. The
MAP30/40/42 series is configured to the international standard 3.00"
x 5.00" footprint. Input and output connections are made via popular
single row Molex connectors.
Single output models feature wide-range output adjustability to meet a
wide variety of standard and user specific output voltage requirements.
MAP30-1005
MAP42-1005
MAP42-1012
MAP42-1024
NOTES:
5V
5V
12V/15V
24V/28V
4.7V to 5.8V
4.7V to 5.8V
11.0V to 18.0V
23.0V to 29.0V
6A
8A
3.4/2.7A (Note 3)
1.7/1.4A (Note 3)
8A
11A
4.6/3.7A (Note 3)
2.3/1.9A (Note 3)
0.2%
0.2%
0.2%
0.2%
±1%
±1%
1%
1%
1%
1%
1%
1%
4.9V to 5.1V
4.9V to 5.1V
11.9V to 12.1V
23.8V to 24.2V
1) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
2) Peak ratings may be used as maximum output current with 100 Linear Feet per Minute (LFM) forced air cooling.
3) MAP42-1012 output currents are expressed as 12V/15V operation. MAP42-1024 output currents are expressed as 24V/28V operation.
MULTIPLE OUTPUT MODEL SELECTION CHART –
40W CONTINUOUS OUTPUT POWER
MODEL
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
OUTPUT
CURRENT
PEAK OUTPUT
CURRENT (NOTE 1)
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%p-p (NOTE 2)
INITIAL SETTING
ACCURACY
MAP40-3000
MAP40-3100
MAP40-3101
MAP40-3105
MAP40-3500
MAP40-3003
+5V
+12V
-12V
+5V
+12V
-12V
+5V
+24V
-12V
+5V
+12
-5V
+5V
+12V
-12V
+5V
+15V
-15V
4.75V to 5.50V
Fixed
Fixed
4.75V to 5.25V
Fixed
Fixed
4.75V to 5.25V
Fixed
Fixed
4.7V to 5.8V
Fixed
Fixed
4.7V to 5.8V
Fixed
Fixed
4.7V to 5.8V
Fixed
Fixed
3A
2A
0.3A
3A
2A
0.3A
3A
1A
0.3A
3A
2A
0.5A
5A
1A
0.3A
3A
1.5A
0.2A
5A
3.5A
0.5A
5A
3.5A
0.5A
5A
1.5A
0.5A
5A
3.5A
1.0A
6A
3.5A
0.5A
5A
3A
0.5A
0.2%
1%
1%
0.2%
1%
1%
0.2%
1%
1%
0.2%
1%
1%
0.2%
1%
1%
0.2%
1%
1%
2%
3.5% (Note 3)
2% (Note 4)
2%
3.5% (Note 3)
2%
2%
3.5% (Note 3)
2%
2%
3.5% (Note 3)
2%
2%
3.5% (Note 3)
2%
2%
3.5% (Note 3)
2% (Note 4)
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
4.9V to 5.1V
11.5V to 12.5V
-11.4V to -12.6V
4.9V to 5.1V
11.5V to 12.5V
-11.4V to -12.6V
4.9V to 5.1V
23.0V to 25.0V
-11.5V to -12.5V
4.9V to 5.1V
11.5V to 12.5V
-4.75V to -5.25V
4.9V to 5.1V
11.5V to 12.5V
-11.4V to -12.6V
4.9V to 5.1V
14.7V to 15.3V
-14.3V to -15.7V
NOTES :
1) Peak loads for 30 seconds or less are acceptable, (10% duty cycle max.).
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
3) Quasi regulated output. See Regulation Curves for more information.
4) Requires a minimum load of 0.5A on V1 or 0.3A on V2.
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments,
or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are
subject to change without notice.
Rev. 10/2000