MAP55 SERIES
INPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Input Voltage - AC
Input Frequency
Brown Out Protection
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Operating Frequency
Continuous input range.
AC input.
Lowest AC input voltage that regulation is maintained with full rated loads.
Nominal AC Input Voltage (115VAC), full rated load.
90 VAC (55W load).
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 264VAC (one cycle). 25° C.
Switching frequency of power supply (varies with load).
90
175
47
90
20
1.6
132
264
63
VAC
Hz
VAC
ms
A
RMS
A
PK
kHz
38
22
180
OUTPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Efficiency
Minimum Loads
Ripple and Noise
Output Power
Overshoot / Undershoot
Regulation
Transient Response
Turn-on Delay
Turn-on Rise Time
NOTES:
Full load, 115VAC. Varies with distribution of loads among outputs.
73
MAP55-1012
0.21
MAP55-1024
0.11
MAP40-1005 and all multiple output models, main channel only.
0.50
Full load, 20MHz bandwidth.
Continuous output power, all multiple output models.
Peak output power (60s maximum, 10% duty cycle), all multiple output models.
Output voltage overshoot/undershoot at turn-on, V1, V2.
Varies by output. Total regulation includes: line changes from 90-132 VAC or 175-264 VAC,
changes in load starting at 20% load and changing to 100% load.
Recovery time, to within 1% of initial set point due to a 50-100%
load change, 4% max. deviation. (Main output of multiple output units).
Time required for initial output voltage stabilization.
1
Time required for output voltage to rise from 10% to 90% (Note 1).
%
Amps
See Model Selection Chart.
55
Watts
65
Watts
1
%
See Model Selection Chart.
500
4
7
µs
Sec
ms
1) Nominal rise time for MAP55-1024 is 36 msec.
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Overvoltage Protection
Overload Protection
MAP40-1005
5.5
6.8
MAP55-1012
17.5
19.7
MAP55-1024
32.0
36.0
Main output only of multiple output units.
5.6
6.8
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
V
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Agency Approvals
Dielectric Withstand
Voltage
Electromagnetic
Interference,
Conducted
Insulation Resistance
Leakage Current
UL1950.
CSA 22.2 No. 234/950.
EN60950 (TUV).
Input to output.
FCC CFR title 47 Part 15 Sub-Part B - conducted & radiated.
EN55022 / CISPR 22 conducted.
EN55022 / CISPR 22 radiated.
Input to output.
Per EN60950, 264VAC.
Approved.
2600
B
B
A
7
500
VDC
Class
MΩ
µA
2