MPB150 Dual-Output AC-DC Series Data Sheet
Input Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Input Voltage- AC
Input Frequency
Brownout Protection
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Power Factor Circuitry
Operating Frequency
Continuous input range.
AC Input.
Lowest AC input voltage that regulation is maintained with full rated loads.
Over full AC input voltage range at full rated load.
90 VAC at full rated load.
Non-user serviceable internally located AC input line fuse, 250 VAC, 3.15A.
Internally limited by thermistor,
110VAC:
one cycle, 25° C.
220VAC:
Active PFC meets requirements of EN61000-3-2.
Switching frequency of main transformer.
90
47
90
17
264
63
2.2
23
46
45
VAC
Hz
VAC
ms
A
RMS
A
PK
kHz
Output Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Efficiency
Minimum Loads
Ripple and Noise
Output Power (Note 1)
Overshoot /Undershoot
Regulation
Transient Response
Turn-on Delay
Turn-on Rise Time
Full Load, 230VAC. Varies with distribution of loads among outputs.
V1 load for full regulation on V2. All models operate
at no load without any damage and meet all specs on V1 above 0 amps.
Full load, 20 MHz bandwidth.
At 15 CFM forced-air cooling. See Application Note for details.
Convection: Consult Factory.
Output voltage overshoot/undershoot at turn-on.
Varies by output. Total regulation includes: line changes from 85-132 VAC
or 170-264 VAC, changes in load starting at 20% load and changing to 100% load.
Maximum deviation due to a 25% load change with unit at 75% load.
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
75
5
80
85
%
Watts
See Model Selection Chart
150
10
See Model Selection Chart
3
0.2
0.2
1.5
20
Watts
%
%
Sec
ms
Interface Signals and Internal Protection
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Overvoltage Protection
Overload Protection
Remote Sense (Note 1)
Power Good Signal
MPB150-2012
13.5
MPB150-2024
26.9
MPB150-2048
57.6
Fully protected against output short circuit or overload. Automatic recovery upon
removal of overload condition.
Total (+sense and -sense) voltage compensation for cable losses.
AC/DC indicator - This signal indicates the status of the AC input or DC outputs.
When there is sufficient AC voltage and the outputs are operating normally, an
open collector signal is provided.
Turn-On delay time from application of AC:
50
Warning time before outputs go out of regulation:
5
Warning time before outputs deviate ±10% from the nominal value:
15
Sink Current
Pull-up Voltage
Provided on dual-output models. Open collector signal intended to drive an LED.
Closed collector occurs when the Power Good Signal is in its open collector state.
Sink Current
Pull-up Voltage
Protected against overtemperature conditions.
Unit recovers when overtemperature condition is removed.
Up to 4 units can be connected in parallel.
There are some limits for parallel operation. See Applications Note.
N+1 redundancy is provided. V2 needs an external isolation diode for N+1 operation.
Internal isolation diode is provided on V1.
V1 output.
16.5
31.1
62.4
VDC
500
mV
500
ms
20
30
mA
V
Power Supply OK Signal
20
30
mA
V
Thermal Shutdown
Current Share
Isolation Diode
NOTES:
1) Negative (-) sense must be connected to output common or load common for proper power supply operation.
APR 28, 2006 revised to JAN 24, 2007
Page 2 of 4
www.power-one.com