MPB80 SERIES
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
AC Input Harmonic Distortion
Agency Approvals
Dielectric Withstand Voltage
Electromagnetic Interference,
Conducted
Input Transient Protection
Insulation Resistance
Leakage Current
In compliance per EN61000-3-2.
UL1950.
CSA 22.2 No. 234/950.
EN60950 (TÜV).
Input to output, 1 second.
FCC CFR title 47 Part 15.
EN55022 / CISPR 22
EN61000-4-5 class 3.
Input to output.
Per EN60950, 264 VAC.
Approved
2600
B
B
2
10
1.0
VDC
Class
kV
M
mA
ENVIRONMENTAL SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Altitude
Cooling
Operating Temperature
Storage Temperature
Relative Humidity
Shock
Vibration
Operating.
Non-Operating.
See model selection table for individual convection/forced air rating.
At 100% load.
Derate linearly above 50°C by 2% per °C.
Non-condensing.
Peak acceleration.
Random vibration, 10 Hz to 2 kHz, 3 axis.
10k
30k
0
0
-40
50
70
85
95
20
6
ASL Ft.
°C
°C
%
G
PK
G
RMS
3