PerFormanCe POWER PFC250
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Agency Approvals
Dielectric Withstand Voltage
Electromagnetic Interference
ESD Susceptibility
Radiated Susceptibility
EFT/Burst
Input Transient Protection
Insulation Resistance
Leakage Current
UL1950.
CSA 22.2 NO. 234/950.
EN60950 (TÜV).
Input to Output per EN60950.
FCC CFR title 47 Part 15 Sub-Part B - Conducted.
EN55022 / CISPR 22 Conducted.
Per EN61000-4-2, level 4.
Per EN61000-4-3, level 3.
Per EN61000-4-4, level 4.
Per EN61000-4-5 level 3.
Input to Output.
Per EN60950, 264 VAC.
Approved
2600
B
B
8
10
±4
1
2
10
1500
VDC
Class
kV
V/M
kV
kV
M
A
Line to Line
Line to Ground
ENVIRONMENTAL SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Altitude
Operating Temperature
Operating.
Non-Operating.
Derate linearly above 50°C by 2.5% per °C.
At 100% load:
At 50% load:
0
-55
0°C to 70°C (after 15 minute warmup).
Non-Condensing.
Peak acceleration.
Random vibration, 10 Hz to 2 kHz, 3 axes.
±0.02
5
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
Vibration
10k
40k
50
70
85
±0.05
95
20
6
ASL Ft.
ASL Ft.
°C
°C
°C
%/°C
%RH
G
PK
G
RMS
OPTIONS
DESCRIPTION
NOTES
SIZE IMPACT
Metric Mounting
Fan
Add “M” as a suffix to the model number to order chassis with
M4 x 0.7 mounting inserts.
Add “F” as a suffix to the model number to order integral fan.
Adds 1.5” (38.1mm) to overall length and 0.5” (12.7mm) to height.
8.50" x 4.75" x 2.00"
(215.9mm x 120.7mm x 50.8mm)
10.00” x 4.75” x 2.50”
(250.4mm x 120.7mm x 63.5mm)
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems,