欢迎访问ic37.com |
会员登录 免费注册
发布采购

VI-AIM-M1 参数 Datasheet PDF下载

VI-AIM-M1图片预览
型号: VI-AIM-M1
PDF下载: 下载PDF文件 查看货源
内容描述: AC输入模块 [AC INPUT MODULE]
分类和应用: 输入元件
文件页数/大小: 1 页 / 434 K
品牌: POWERBOX [ Powerbox ]
   
VI-AIM
A C
I N P U T
M O D U L E
MODULES
Features
Universal input: 85 to 264VAC
Output power: 250 watts
Operating temperature: 100°C
97% efficiency
EMI/RFI filtering to FCC/VDE, Class A
Input transient protection
Inrush limiting
UL, CSA, TUV, VDE, BABT, CE, C-Tick
Specifications
INPUT
AC line input
Frequency
Inrush current (max.)
Transient surge withstand
EMI/RFI filtering
OUTPUT
Output pPower
Max. value of holdup
capitance
EMI/RFI
C-Tick
Safety
250W
1200µF
85–264VAC
47Hz–440Hz
<40A pk
Normal Mode: 1.2/50µs, 3kV Pulse, 2-Joules
Yes
OPERATING
Efficiency
Isolation voltage
97%
Input – Output: NoneInput – Baseplate –
Output: 1500V rms
0.4°C per watt
58x61x13mm
Add L to model e.g. VI-LAIM-E1
Baseplate operating temp. 100°C
Thermal resistance
MECHANICAL
Dimensions
Mega module packaging
option:
Selection Table
MODEL
NUMBER
VI-AIM-E1
VI-AIM-C1
VI-AIM-I1
VI-AIM-M1
PRODUCT
GRADE
E-Grade
C-Grade
I-Grade
M-Grade
OPERATING
TEMP.
-10°C to +100°C
-20°C to +100°C
-40°C to +100°C
-55°C to +100°C
STORAGE
TEMPERATURE
-20°C to 105°C
-40°C to +105°C
-55°C to +105°C
-65°C to +105°C
STANDARDS AND APPROVALS
VDE/FCC Class A
AS/NZS CISPR11 Group 1 Class A
UL544, 1950; CSA C22.2 No.234, 950, TÜV
IEC90, VDE EN60950
Compatible with VI-200/VI-J00
VI-X7X (85–264VAC)
Typical Configuration
VI-AIM CONNECTION
VI-X6X (170–264VAC)
VI-X5X (85–135VAC)
Note: For RoHS version replace VI with VE.
VI-AIM BLOCK DIAGRAM
Your dependable power partner – www.powerbox.com.au