HGN-365A
IEC 60320 INLET SOCKET WITH SINGLE OR DOUBLE FUSE HOLDER,
SNAP-IN OR FLANGE MOUNT
MECHANICAL DIMENSIONS
(Unit: mm)
SNAP-IN
30.8
28.3
28.5
31.0
33.0
35.0
32.3
Use only with a 250V Fuse
SUGGESTED PANEL CUTOUT
(MOUNTING FROM FRONT)
THICKNESS OF PANEL IS FROM
1.00mm to 1.6mm
FEATURES
The HGN-365A filter series offers a wide variety of options
with a current rating up to 10A, 250VAC. This power entry
module offers industry standard 5 x 20mm fuse/s with IEC
connector. This series offers an option of having a single or
double fuse in the same package. These filters are also used
for health care equipment and offer extremely low leakage
current to comply with UL544 & 2602.
A Ground Choke can be added to enhance the grounding
ability of the circuit. A bleeder resistor can also be added to
prevent excessive voltages from developing across the filter
capacitors when there is no load.
2x
6
33.0
Use only with a 250V Fuse
42.6
48.5
(58.4)
6.3
27.8
31.0
FLANGE MOUNT
28.3
36.0
28.0 Max
31.0
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
2x
3.6
32.4 Typ.
2x
3.6
RECOMMENDED
PANEL CUTOUT
(MOUNTING FROM FRONT)
36.0
44.0
TECHNICAL DATA
•
Rated Voltage: 115/250VAC
•
Rated Current: 1A, 2A, 3A, 4A, 6A, 8A, 10A
•
Power Line Frequency: 50/60Hz
•
Max. Leakage Current each
Line to Ground:
@ 115VAC 60Hz: 0.5mA
@ 250VAC 50Hz: 1.0mA
@ 115VAC 60Hz: 2
µ
A*
@ 250VAC 50Hz: 5
µ
A*
•
Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
•
Temperature Range: -25C to +85C
* Medical application
Panel Thickness 1mm to 1.6mm
(58.4)
48.5
42.6
6.3
27.8
31.0
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
70
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: filtersales@powerdynamics.com •
www.powerdynamics.com