HGN-375(A, B, C)
FUSED WITH ON/OFF SWITCH, IEC 60320 POWER INLET
SOCKET WITH FUSE/S (5X20MM)
MECHANICAL DIMENSIONS
(Unit: mm)
CASE A
49.83
60.71
55.04
65.4
Use only with a 250V Fuse
Employer uniqement avec
un fusible de 250V
60.0
O
32.45
-
40 + 0.2
3.5
49.37
2x M3
61.5
CASE B
FEATURES
2x 3.3
The HGN-375(A, B, C) series offers filters in three different
package styles - Flange mount (sides), Flange mount (top/
bottom), & snap-in type. This cost effective series offers more
component options with better performance in curbing
common and differential mode noise. These filters are
equipped with IEC connector, fuse holder for one or two 5 x
20 mm fuses, 2 pole on/off switch and fully enclosed metal
housing.
These filters are also available for Medical equipment with
low leakage current and have been designed to bring various
medical equipments into compliance with EN55011 and FCC
Part 15J, Class B conducted emissions limits.
82
72
Use only with a 250V fuse
Employer uniquement avec
un fusible de 250V
28.5
4x R0.5
6.30 TYP.
-
40.0+ 0.2
RECOMMENDED PANEL CUTOUT
(MOUNT FROM FRONT)
R2.5 TYP.
2x 3.5
29.3
+0.5
60.8
+0.5
72.0
+0.1
29 6.3 TYP.
29.5
59.8
48.7
(3.5)
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
CASE C
(61.3)
(56.2)
TECHNICAL DATA
•
Rated Voltage: 125/250VAC
•
Rated Current: 1A, 2A, 3A, 4A, 6A, 10A
•
Power Line Frequency: 50/60Hz
•
Max. Leakage Current each
Line to Ground:
@ 115VAC 60Hz: 0.5mA, max
@ 250VAC 50Hz: 1.0mA, max
@ 125VAC 60Hz: 2
µ
A*, max
@ 250VAC 50Hz: 5
µ
A*, max
•
Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
•
Temperature Range: -25C to +85C
* Medical application
65 59.5
Use only with a 250V fuse
Employer uniquement avec
un fusible de 250V
59.8
28
32
SUGGESTED PANEL CUTOUT
(MOUNTING FROM FRONT)
THICKNESS OF PANEL IS FROM
1.00mm to 1.6mm
48.7
(3.5)
R2.5 TYP.
29.3
+0.5
29 6.3 TYP.
61.4
+0.3
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: filtersales@powerdynamics.com •
www.powerdynamics.com
81